Administrator action
Contact Dell EMC PowerScale Technical Support to determine if one of the components or motherboard must be replaced on
the node or nodes.
800010008
The NVRAM journal is larger than the journal backup partition.
Description
The system has resized the journal partition.
Administrator action
This message is informational. No action is required.
800010009
There was an error calculating the partition size of the NVRAM journal backup.
Description
The system is resetting the partition to the default size of 512 MB.
Administrator action
This message is informational. No action is required.
800010010
A node was unable to verify the backup copy of its journal on its peer node.
Description
There are two possible issues that might result in this event:
●
The local copy of a node's journal is not valid.
●
There was an error when a node tried to verify the local copy of its journal against the mirror copy of its journal on its peer
node.
Administrator action
If the link between peer nodes has been temporarily interrupted then this event will resolve when the link between the two
nodes is reestablished.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to