100010046
A node pool has a node whose SSD count does not match the SSD counts of other nodes in the pool.
Description
A mismatch of the number of SSDs in nodes in a pool can be caused by an SSD failure in one of the nodes in the pool or, in the
case of Generation 6 hardware, nodes do not contain the same number of cache SSDs and L3 cache is not enabled for the node
pool.
Administrator action
In the case of a failed SSD, replace the failed drive. In the case of Generation 6 hardware, where the cache SSD counts of
nodes in the chassis do not match, either turn L3 cache on for the node pool, or add cache SSDs to ensure that every node
contains the same number of cache SSDs.
100010050
The smartfail process completed on a drive.
Description
A drive has been smartfailed from the cluster. The event message provides you with the chassis serial number, node, sled, the
drive slot number within the sled, drive type, and Logical Number (LNUM) of the drive.
Administrator action
Replace the smartfailed drive with a new drive according to the instructions in the
PowerScale Drive Replacement Guide
for
your platform.
100010051
The smartfail process completed on a drive.
Description
A drive has been smartfailed from the cluster. The event message provides you with the chassis serial number, node, sled, the
drive slot number within the sled, drive type, and Logical Number (LNUM) of the drive.
Administrator action
Replace the smartfailed drive with a new drive according to the instructions in the
PowerScale Drive Replacement Guide
for
your platform.