Ensure that the NVDIMM is replaced in the correct slot.
●
For an end of life, bad, or degraded NVDIMM replace the NVDIMM.
900100031
NVDIMM in the chassis ({chassis}) is in the wrong DIMM slot.
Description
NVDIMM was replaced in the wrong DIMM slot. Refer to the OEM manual for proper DIMM replacement procedure.
Administrator action
Replace the NVDIMM in the correct slot.
900100032
NVDIMM subsystem health is not being monitored in the chassis ({chassis}). Until the issue is resolved, setting the node to
read-only
Description
NVDIMM subsystem health is not being monitored. Node will transition to read-only mode until the issue has been resolved.
Causes: Dell PowerTools is not responding to service requests.
Note: The monitoring subsystem will attempt several times before going read-only and triggering this event. Currently it is set to
100 seconds. This is subject to change as per the monitoring subsystem configuration of this node.
Administrator action
Check services, if issues persist, contact Technical Support.
900110001
The internal or ambient temperature around a node has exceeded the allowable threshold for the CPU.
Description
Ambient temperature is only measured by front panel sensors. If you receive an event that indicates that the front panel is out
of specification, the temperature in your data center might need to be adjusted.
If a node is subjected to high temperatures for an extended period of time, the CPU is throttled and the node goes into read
only-mode to help prevent potential data loss due to component failure. If the node temperature reaches critical levels, it is
possible that the node will shut down entirely.
Administrator action
Perform the following steps in the order listed. If the issue resolves after a step, there is no need to complete the subsequent
steps.