Figure 40. Removing an AC PSU
1.
release latch
2.
PSU cable connector
3.
PSU
4.
power connector
5.
PSU handle
Next steps
•
If applicable, install the AC PSU.
•
If applicable, install the PSU blank.
Related links
Safety instructions
Installing an AC power supply unit
Installing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
NOTE: The maximum output power (shown in watts) is listed on the PSU label.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
For systems that support redundant power supply units (PSUs), ensure that both the PSUs are of the same type and have the
same maximum output power.
3.
If installed, remove the PSU blank.
Steps
1.
Slide the PSU into the chassis until the PSU is fully seated and the release latch snaps into place.
2.
If applicable, relatch the cable management arm.
For information about the cable management arm, see the rack documentation of your system.
3.
Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION: When connecting the power cable, secure the cable with the strap.
97