1.
In the system tree, go to Chassis Overview
→
Server Overview and then click Setup
→
Slot Names. The Slot
Names page is displayed.
2.
In the Slot Name field, edit the slot name. Repeat this step for each slot you want to rename.
3.
To use the server’s host name as slot name, select Use Host Name for the Slot Name option. This override the
static slot names with the server’s Host Name (or system name), if it is available. This requires the OMSA agent to
be installed on the server. For more details on the OMSA agent, see the
Dell OpenManage Server Administrator
User's Guide
.
4.
Click Apply to save the settings.
5.
To restore the default slot name (SLOT-01 to SLOT-16, based on the server's slot position) to the server, click
Restore Default Value.
Configuring iDRAC Network Settings
You can configure installed or newly inserted server's iDRAC network configuration settings. A user can configure one
or more installed iDRAC devices. The user can also configure the default iDRAC network configuration settings and root
password for severs that are installed later; these default settings are the iDRAC QuickDeploy settings.
For more information about iDRAC, see the
iDRAC7 User’s Guide
at dell.com/support/manuals.
Related Links
Configuring iDRAC QuickDeploy Network Settings
Modifying iDRAC Network Settings for Individual Server iDRAC
Modifying iDRAC Network Settings Using RACADM
Configuring iDRAC QuickDeploy Network Settings
Use the QuickDeploy Settings to configure the network settings for newly inserted servers. After enabling QuickDeploy,
the QuickDeploy settings are applied to servers when that server is installed.
To enable and set the iDRAC QuickDeploy settings using the CMC Web interface:
1.
In the system tree, go to Server Overview, and then click Setup
→
iDRAC. The Deploy iDRAC page is displayed.
2.
In the QuickDeploy Settings section, specify the settings mentioned in the following table.
Table 12. : QuickDeploy Settings
Setting
Description
QuickDeploy Enabled
Enables or disables the QuickDeploy feature that
automatically applies the iDRAC settings configured on
this page to newly inserted servers; the auto
configuration must be confirmed locally on the LCD
panel.
NOTE: This includes the root user password if the
Set iDRAC Root Password on Server Insertion box
is checked.
By default, this option is disabled.
Set iDRAC Root Password on Server Insertion
Specifies whether a server’s iDRAC root password must
be changed to the value provided in the iDRAC Root
Password field when the server is inserted.
iDRAC Root Password
When Set iDRAC Root Password on Server Insertion
and QuickDeploy Enabled options are selected, this
86
Summary of Contents for Chassis Management Controller
Page 1: ...Dell Chassis Management Controller Firmware Version 4 3 User s Guide ...
Page 42: ...42 ...
Page 56: ...56 ...
Page 84: ...84 ...
Page 98: ...98 ...
Page 104: ...104 ...
Page 130: ...130 ...
Page 136: ...136 ...
Page 200: ...200 ...
Page 214: ...214 ...