– Enable 110 VAC PSUs:
racadm config -g cfgChassisPower -o
cfgChassisAllow110VACOperation 1
– Enable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1
– Disable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 0
– To enable the power remote logging feature, enter the following command:
racadm config -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingEnabled 1
– To specify the desired logging interval, enter the following command:
racadm config -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingInterval n
where n is 1-1440 minutes.
– To determine if the power remote logging feature is enabled, enter the following command:
racadm getconfig -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingEnabled
– To determine the power remote logging interval, enter the following command:
racadm getconfig -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingInterval
The power remote logging feature is dependent on remote syslog hosts having been previously configured.
Logging to one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This
can be done either through the web GUI or the RACADM CLI. For more information, see the remote syslog
configuration instructions.
– To enable remote power management by PM3, type:
racadm config -g cfgChassisPower -o
cfgChassisServerBasedPowerMgmtMode 1
– To restore CMC power management, type:
racadm config -g cfgChassisPower -o
cfgChassisServerBasedPowerMgmtMode 0
For information about RACADM commands for chassis power, see the config, getconfig, getpbinfo, and
cfgChassisPower sections in the
RACADM Command Line Reference Guide for iDRAC7 and CMC
.
Executing Power Control Operations
You can execute the following power control operation for the chassis, servers, and IOMs.
NOTE: Power control operations affect the entire chassis.
Related Links
Executing Power Control Operations on the Chassis
Executing Power Control Operations on a Server
Executing Power Control Operations on an IOM
Executing Power Control Operations on the Chassis
CMC enables you to remotely perform several power management actions, such as an orderly shutdown, on the entire
chassis (chassis, servers, IOMs, iKVM, and PSUs).
196
Summary of Contents for Chassis Management Controller
Page 1: ...Dell Chassis Management Controller Firmware Version 4 3 User s Guide ...
Page 42: ...42 ...
Page 56: ...56 ...
Page 84: ...84 ...
Page 98: ...98 ...
Page 104: ...104 ...
Page 130: ...130 ...
Page 136: ...136 ...
Page 200: ...200 ...
Page 214: ...214 ...