Rev 2022-03-08
Pharmafill Model TC3 User Manual
Deitz Company Inc.
TC3 User Manual
Page 55
10.3 – TROUBLESHOOTING (Cont’d)
7. Disc and Feeder stop before target count in reached
❑
Check Disc+Feeder override switch is in the AUTO position (up)
❑
Check Slowdown % is not set to zero
❑
Press RESET and try again
8. Feeder stops too often (if equipped with Auto Feed Sensor)
❑
Check mechanical adjustments of the Auto-feed Sensor (center hub)
❑
Check function of the Auto-feed Sensor (center hub)
9. Count is not accurate – too many in container (large error)
❑
Check Counting Sensor adjustment – One-shot Delay not too long
❑
Check Counting Head is properly centered on product flow.
❑
Check adjustment of product guides – no doubles getting through
10. Count is not accurate – too few in container (large error)
❑
Clear gels or product with hole - Check Counting Sensor adjustment – One-
shot Delay too short
❑
This is very rare – possibly due to electrical interference from nearby
machinery
11. Count is not accurate – small error, random over/under
❑
Check product flow down exit chute – sliding freely and adequate separation
❑
Check setting of Flag Delay using Fill One Mode.
❑
Check Counting Head is properly centered on product flow.
❑
Check adjustment of product guides – no doubles getting through
❑
Check Counting Sensor adjustment – One-shot Delay not too long
❑
Check Counting Sensor adjustment – try various Threshold settings
❑
Check Counting Sensor for dust buildup
Summary of Contents for Pharmafill TC3
Page 1: ...Model TC3 Electronic Counter Operation Manual...
Page 44: ...Rev 2022 03 08 Pharmafill Model TC3 User Manual Deitz Company Inc TC3 User Manual Page 32...
Page 69: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......