Rev 2022-03-08
Pharmafill Model TC3 User Manual
Deitz Company Inc.
TC3 User Manual
Page 44
9.2 - Breakdown Of Remove-To-Clean Contact Parts (Illustrated) (Cont’d)
13. Remove the
Counting Sensor Cover
. Slide
the
Counting Sensor
to the right to remove it
from two the mounting pins.
14. Remove the
Counting Window
and
Counting Sensor
as one unit. Do not disconnect
the fiber optic cables from the top of the Counting
Sensor.
15. Remove the
Funnel Holder
and the
Funnel
.
16. Remove the
Clear Front Cover
.
COUNTING
WINDOW
COUNTING
SENSOR
COVER
COUNTING
SENSOR
CLEAR
FRONT
COVER
FUNNEL
HOLDER &
FUNNEL
Summary of Contents for Pharmafill TC3