7.3 - Run Mode (cont’d)
5.
Bottle Supply Error
– Filling stops when there
is no bottle at the Supply sensor on the conveyor.
Restarts automatically when a bottle is detected.
6.
Bottle Backup Error
– Filling stops when
there is a bottle detected at the Backup sensor on
the conveyor. Restarts automatically when no
bottle is detected.
7.
Trap Full Error
– As a filled bottle is being
replaced, the pills flow into the closed trap. This
message is displayed and filling stops if the
Current Count exceeds the preset Trap Max Count
while the trap is closed. When the next bottle does
arrive, the error is corrected and the message will
read “
TrapError – Press CLR
”. Does not restart
automatically. You must press
CLEAR
.
8.
RESET Button
– Press this button to cause the
Current Count to go to zero and flip the Divider
flag to the other side.
In RUN mode, filling will continue.
In FILL ONE mode or CHECK COUNT
mode, filling will stop.
9.
TRAP Button
– The trap flag position (left or
right) in controlled automatically. To temporarily
change the position of the trap flag, press and hold
this button. The trap flag will switch to the other
side. When the button is released, the flag will
return to the automatic position.
Summary of Contents for Pharmafill TC3
Page 1: ...Model TC3 Electronic Counter Operation Manual...
Page 44: ...Rev 2022 03 08 Pharmafill Model TC3 User Manual Deitz Company Inc TC3 User Manual Page 32...
Page 69: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......