Pharmafill Model TC3 User Manual
Deitz Company Inc.
TC3 User Manual
Page 23
7.9 - Menu 5. Check Count
In
Check Count
mode, the machine will count
continuously. The Target Count, Slowdown Count
and Trap Max Count are ignored. The divider flag
will not flip automatically, the trap will stay open
and bottles will not be indexed. This mode is used
to:
•
count the contents of a container
•
run accuracy and speed tests.
•
run all the product out of the machine
1. Press
MENU
2. Use the
UP
or
DOWN
arrow buttons to
scroll to “
5. Check Count
”.
3. Press (and release)
ENTER
to select Check
Count mode.
4. If you intend to keep track of the count, be sure
to press
RESET
to set the
Current Count
to zero
before starting.
5. Press
ENTER
to begin counting.
Blower Delay
– Before filling begins, there is
a 5 second delay to allow the air blower to
come up to speed.