Pharmafill Model TC3 User Manual
Deitz Company Inc.
TC3 User Manual
Page 36
8.3 - Bottle Sensor Positioning
BOTTLE SENSORS
There are three photoelectric fiber optic bottle
sensors. They must be positioned along the
conveyor rail so that the light source will shine
directly at the side of the bottle when the bottle is
stopped in a line with other bottles.
1. The
Supply Bottle Sensor
is positioned
upstream from the filling station, to assure a
supply of empty bottle is available.
2. The
Start Bottle Sensor
must be positioned on
the bottle in the filling station. It may be
necessary to angle the sensor slightly to get a
straight on look at the bottle. Use a ¼” open
wrench to adjust the angle bracket. Do not
position it at a bottle upstream, or errors at the
filling position will not be detected.
3. The
Backup Bottle Sensor
in positioned
downstream from the filling station, to detect if
bottles backup from a downstream stoppage,
which could interfere with the release of bottles
from the filling station.
4. You can check the status of the all three bottle
sensors can by looking through the
Bottle Sensor
Status
window in the control panel. The green
light indicates power is on and the yellow light
indicates an output signal (bottle detected).
SUPPLY
BOTTLE
SENSOR
START
BOTTLE
SENSOR
BACKUP
BOTTLE
SENSOR
Summary of Contents for Pharmafill TC3
Page 1: ...Model TC3 Electronic Counter Operation Manual...
Page 44: ...Rev 2022 03 08 Pharmafill Model TC3 User Manual Deitz Company Inc TC3 User Manual Page 32...
Page 69: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......