AXE 6 Digit Microprocess Counter (72x72mm)
MC726 Series
■Features
◎
Accept more type sensors(switch,encoder,proximity.etc)
◎
Quadrature sensing up to 4 times resolution
◎
Accept input rates up to 10KHz
◎
Alarm output can programmable per-warn mode
◎
Readout range from -199999~999999
◎
N,R,C alarm control mode
◎
Four counting modes Up,Down,Up/Down,Quadrature
◎
Alarm output action times 0.1~99.9 sec. Can be modified
◎Power down saving
◎
0.36
”
highlight display
◎
Decimal point can be modified
◎
Man-machine interface,easy to operate
◎
Input scaling multiplied 0.00001~9.99999 can be modified
◎
EEPROM Saving,data safekeeping about 10 years
◎
Reset by panel or connect terminal
◎
Modified inside parameter,must have pass code
■Name of parts
■Connect diagram
◎Contact input
(PNP)
◎CMOS input
(12V or 15V)
◎Sensor input
(PNP 12V)
◎Contact input
(NPN)
◎TTL input
(5V)
◎Sensor input
(NPN 12V)
■Alarm output control mode description
◎N(MANUAL): When count value equal setting value the relay ON & continue count until reset by panel or connect terminal
then relay OFF & count value return to RST setting value
◎R(RETURN): When count value equal setting value the relay ON & continue count until relay action time out then relay
OFF & count value return to RST setting value
◎
C(CONTINUE): When count value equal setting value the relay ON & count value return to RST setting value then continue
count & relay action time out the relay OFF
◎
N/R/C control mode is according to AL1 setting value
◎
WARN: When count to [AL1 value(digit 1~4)
-
warn value(digit 5~6)]RELAY 2 ON , count to AL1 value RELAY 1 ON
COM
IN
12V
Inside jumper
1
2
3
4
OFF ON ON OFF
COM
IN
12V
Inside jumper
1
2
3
4
OFF ON OFF OFF
COM
IN
12V
Inside jumper
1
2
3
4
OFF ON OFF OFF
COM
IN
12V
Inside jumper
1
2
3
4
ON OFF OFF OFF
COM
IN
12V
Inside jumper
1
2
3
4
OFF ON OFF ON
COM
IN
12V
Inside jumper
1
2
3
4
ON OFF ON OFF
GND
GND
Sensor
Sensor
1
2
6
5
4
3
RST
ENT
AL
SEL
OUT1 OUT2 OUT3
AL1 AL2
PV
SV
Count value display
Setting value display
Per digit setting keys
Function keys