Test set-up featuring optional TERA Wall attachment
Operating column.
17.9 Wall attachment with operating
column
17.9.1 Description
The Wall attachment has been developed for semi-
permanent set-up on a (concrete) retaining wall. The
retaining wall attachment is accompanied by an
operating column and standard 30-meter cable. The
wall attachment can be tilted so the spray can be
better directed.
17.8.2. Specifications
Retaining wall width: 400-810 mm
Tilted set-up:
0 to 44°
Total width:
1125 mm
17.8.3 Use
•
Determine the ideal place for the wall
attachment and the operating column.
•
Install the wall attachment and clamp it to the
retaining wall using 4 anchor bolts (2 front and
2 rear).
•
Also clamp the operating column to the base
using anchor bolts.
See chapter 9.2 for operation:
Operation with basic control panel
If the wall attachment is ordered together with the
optional UVC2000 or UVC 5000, then a mounting
bracket for the UVC will also be supplied
17.8.4 Maintenance
Maintain the Tera in accordance with the instructions
in chapter 10.
Inspect the anchor bolts every two months.