DEHACO B.V.
Kruisbaak 25, 2165 AJ Lisserbroek (NL)
Tel.:+31(0)88 20 20 600
www.dehaco.nl
Dehaco Tera 45, 60, 75, 90. Model year 2016 -
16
of
31
- File:User Manual_Tera 400V Dust Control Unit_UVC6000_v3.0_EN.docx
Water filter
11. Malfunctions.
WARNING!
Make sure that malfunctions are only
repaired by qualified and experienced
personnel, and only use original spare
parts.
This will guarantee the safety of the
machine!!
The TERA does not start:
•
Check the emergency stop button; is it off?
•
Check the power supply
(are all phases present?).
•
Switch everything off, wait 30 seconds for the
frequency regulator to reinitialize, and then
restart.
The TERA does not generate enough water
output:
•
Check the capacity of the water supply.
•
Check the water hose
(trapped/damaged/leaking?).
•
Clean the water filter in the base of the TERA:
The water filter is located next to the water
meter (photo, arrow).
-
Open the filter and clean the element.
-
Carefully replace the filter element.
The TERA malfunction after a short period: the
blue light is illuminated (phase error).
Sometimes the red light is illuminated too (error
frequency inverter)
•
Check the extension lead(s): the cross-section
of the leads must be of a sufficient size,
depending on the length. This is a common
problem by an increased distance between
generator and TERA.
Use an extension lead with a larger cross-
section