DEHACO B.V.
Kruisbaak 25, 2165 AJ Lisserbroek (NL)
Tel.:+31(0)88 20 20 600
www.dehaco.nl
Dehaco Tera 45, 60, 75, 90. Model year 2016 -
15
of
31
- File:User Manual_Tera 400V Dust Control Unit_UVC6000_v3.0_EN.docx
10. Maintenance.
WARNING!!
Always remove the plug from the power
socket before inspection, maintenance or
repairs are carried out!!
Daily:
•
Visually check the machine for damage,
certainly to the power cable!
•
Repair or have any minor damage repaired.
This will not only benefit your safety but also
the life span of the machine.
•
Keep the machine clean!! This reduces the risk
of accidents, and works really well!
TAKE NOTE!!
Clean carefully!!!
Do not
spray with a
high pressure cleaner!
!
Every two months:
•
Clean the machine.
•
Spray moving parts with WD 40.
Tightening torques.
The following tightening torques can be used for 8.8
hexagonal bolts. (Wurth)
:
M8x 1.25-8.8 25 Nm.
M10x 1.5-8.8 50 Nm.
M12x 1.75-8.8 90 Nm.
M16x 2.0-8.8 220 Nm.
M20x 2.5-8.8 450 Nm.
CAUTION!!
The Ventilator and Atomizer can NEVER
be connected directly to the main power
supply!! This will cause irreparable
damage to the motor!!
ALWAYS connect both motors via the
frequency regulator!!
The fog canon cannot be reset via
hand-held
remote
control,
smartphone or computer. This must
always be done on the machine itself!!