List of warning and error states
Warning invalid start
sequence
Incorrect turning-on
sequence
Set
Key Switch
to “
0
” and repeat
the turning-on sequence. See
“Turning On sequence” on
page 62
SYSTEM_ALARM
POWER_ON
ENABLE_OUT
OFF
OFF
OFF
System Error
Interlock error
- Check
X3 - SLO connector
sig-
nals (see “X3 - SLO (Safe Laser
Off)” on page 29)
- Check X3 - SLO connector
presence
SYSTEM_ALARM
POWER_ON
ENABLE_OUT
ON
OFF
OFF
CBOX error
- Check if
X1 - Command Box
connector
is present
- Check
X1.10
CONNEC-
TOR_PRESENCE input signal
(see “X1 - Command Box (Laser
Control)” on page 33)
Rack Temperature
error
Check the temperature of the
environment where the control
rack is placed. The temperature
must not exceed the operative
limit
Scan Head
Temperature error
Check the temperature of the
environment where the scan
head is placed. The temperature
must not exceed the operative
limit
Scan Head
Connection error
Contact Datalogic Technical
Support
Source Temperature
error
Check the temperature of the
environment where the control
rack is placed. The temperature
must not exceed the operative
limit
SYSTEM_ALARM
POWER_ON
ENABLE_OUT
ON
OFF
OFF
Source generic error
Contact Datalogic Technical
Support
Source Power Supply
error
Contact Datalogic Technical
Support
Incorrect Firmware
version error
Contact Datalogic Technical
Support
Back reflection error
Check the reflectance of the
material to be marked. Marking
on high reflective material could
damage the laser source.
STATUS LED
DESCRIPTION
POSSIBLE
CAUSE
ACTION
X1 - COMMAND
BOX CONNECTOR
OUTPUT STATE
Blinking ORANGE
Blinking RED