INSTALLATION
20
AREX™ 401
INSTALLATION ENVIRONMENT
Control rack
The control rack must be installed in a suitable environment in order to allow proper air
flow and correct housing of the cables.
The control rack uses a forced air cooling system: an adequate air flow is necessary to
guarantee its correct cooling. Install the control rack so that air flow is not obstructed.
Moreover, do not install it near a heat source.
Clean the air filter when it is dirty. If the air filter is dirty, insufficient air-flow might not
ensure correct cooling and might stop the marking operation. Clean or replace the air
filter periodically.
≥
300mm
Figure 13: Control rack installation environment
CAUTION: If not enough space is provided, the temperature inside the con-
trol rack could rise, causing temperature error.
CAUTION: DO NOT place heavy objects on top of the control rack!
NOTE: The control rack IP rating is IP31 in horizontal position, otherwise
IP30.