TIMING DIAGRAMS
USER MANUAL
47
TIMING DIAGRAMS
Turning On sequence
typ 60s
user defined
within 50ms
user defined
within 50ms
Figure 33: Turning On sequence timing diagram
Marking control signals behavior
T1
T2
T3
T4
T5
T6
NOTE
Figure 34: Marking process timing diagram
REF. NAME
DESCRIPTION
T1
Start Time
Minimum time duration that the START_MARKING signal must have
in order to be accepted as a valid START_MARKING event
T2
Start Delay
Delay between the acceptance of the START_MARKING signal and the
rising edge of the BUSY signal
T3
Busy Advance
Delay between the rising edge of the BUSY signal and the laser emis-
sion
T4
Stop Time
Minimum time duration that the STOP_MARKING signal must have in
order to be accepted as a valid STOP_MARKING event
T5
Busy Delay
Delay between the end of the laser emission and the falling edge of
the BUSY signal
T6
End Time
Time duration of the END signal
Consult Lighter™ software user's manual for a proper use of the same.