CONNECTORS SPECIFICATIONS
USER MANUAL
29
CONNECTORS SPECIFICATIONS
X3 - SLO (Safe Laser Off)
Control rack back panel connector
Socket Sub-D, 15 pins, female.
Figure 19: X3 - SLO connector, female panel plug (front view)
Table 1: X3 - SLO connector pinout
PIN
SIGNAL
TYPE
DESCRIPTION
X3.1
VCC
Power Output
Isolated Auxiliary 24V DC power supply
X3.2
RESERVED
-
DO NOT CONNECT
X3.3
VCC
Power Output
Isolated Auxiliary 24V DC power supply
X3.4
SAFE
Digital Output
Clean contact pole for feedback monitor (Common)
X3.5
SAFETY_FDBK-
Digital Output
Return of clean contact pole for feedback monitor (Normally
Closed)
X3.6
GND
Ground
Isolated Ground reference
X3.7
RESERVED
-
DO NOT CONNECT
X3.8
GND
Ground
Isolated Ground reference
X3.9
INTERLOCK_A
PNP Digital
Input
INTERLOCK_A positive signal (to be connected to VCC)
X3.10
RESERVED
-
DO NOT CONNECT
X3.11
INTERLOCK_B
PNP Digital
Input
INTERLOCK_B positive signal (to be connected to VCC)
X3.12
LASER_STOP_A
PNP Digital
Input
LASER_STOP_A positive signal (to be connected to VCC)
X3.13
/ LASER_STOP_A
NPN Digital
Input
LASER_STOP_A negative signal (to be connected to GND)
X3.14
LASER_STOP_B
PNP Digital
Input
LASER_STOP_B positive signal (to be connected to VCC)
X3.15
/ LASER_STOP_B
NPN Digital
Input
LASER_STOP_B negative signal (to be connected to GND)
CAUTION: For a correct use of the LASER STOP functionality, exclusively
use all PNP inputs or alternatively all NPN inputs (mixed configurations not
allowed).
Summary of Contents for AREX 401
Page 1: ...AREX 401 USER MANUAL InfraRed Fiber Laser Marker...
Page 113: ...SLO INTEGRATION EXAMPLE USER MANUAL 105 SLO INTEGRATION EXAMPLE...
Page 140: ...RECOVER THE LASER MARKER 132 AREX 401 Press FINISH to continue Press YES to continue...
Page 145: ...USER MANUAL 137 APPENDIX G MECHANICAL DRAWINGS...