TECHNICAL CHARACTERISTICS
USER MANUAL
23
PHYSICAL SPECIFICATIONS
Control Rack dimensions (HxWxD)
mm
in
158x432x434
6.22x17x17.1
Control Rack Weight
kg
lbs
23.5
51.8
Control Rack IP Rating
IP31 (in horizontal position, otherwise IP30)
Control Rack Cooling
Forced Air
Rack fans: L10@40°C = 70000 h
Laser source fans: L10@40°C = 65000 h
Scan Head dimensions (HxWxD)
2
mm
in
96x90x326
3.7x3.5x12.8
Scan Head Weight
3
kg
lbs
3.5
7.7
Scan Head IP Rating
4
IP64
Scan Head Cooling
Air Cooling
Noise
dB (A)
<65 at 1 meter
Head Cable minimum bending radius
mm
in
80 (fixed installation); 110 (mobile installation)
3.15 (fixed installation); 4.33 (mobile installation)
Head Cable length
mm
in
2885
113.5
Beam deflection
High speed galvanometer scanning system
OTHER SPECIFICATIONS
Marking speed
5
mm/s
Up to 10000
Char Marking Speed
6
char/s
Up to 600
MOF (marking on fly)
YES (constant speed or encoder)
Line speed - Productivity
m/min
pcs/s
Up to 75
3
Marking Control and Software
EMC (Embedded Marking Control) and Lighter™ Suite
Communication
RS232, Ethernet (TCP/IP 10, 100 Mbit), EtherNet/IP
ProfiNet I/O, TcpServer Protocol, Digital I/O
1. Specification @ 25°C
2. Without F-Theta scan lens
3. Without F-Theta scan lens
4. Using F-Theta scan lens protective cap, see “F-Theta protective cap for M lenses” on page 84
5. May vary: measured with
ƒ
=160mm
6. Single line string, Roman-s font, 1mm height
AREX 401
10C-X6X
Summary of Contents for AREX 401
Page 1: ...AREX 401 USER MANUAL InfraRed Fiber Laser Marker...
Page 113: ...SLO INTEGRATION EXAMPLE USER MANUAL 105 SLO INTEGRATION EXAMPLE...
Page 140: ...RECOVER THE LASER MARKER 132 AREX 401 Press FINISH to continue Press YES to continue...
Page 145: ...USER MANUAL 137 APPENDIX G MECHANICAL DRAWINGS...