CONNECTORS SPECIFICATIONS
USER MANUAL
33
X1 - Command Box (Laser Control)
Control rack back panel connector
Socket Sub-D, 25 pins, female.
Figure 23: X1 - Command Box connector, female panel socket (front view)
PIN
SIGNAL
TYPE***
DESCRIPTION
X1.1
24V_ENABLE_B
Output power
supply
Auxiliary 24V DC power supply available for EXT_ENABLE_B (max
125mA)
X1.2
EXT_ENABLE_B
Digital Input
Secondary external ENABLE signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
X1.3
MARKING_KO
Digital Output
PNP/NPN
configurable
This signal is used to notify a BAD marking:
- ON in case of bad marking (the marking process has been stopped
due to STOP_MARKING signal; laser emission has been interrupted
due to change in the system status; MOF process has been inter-
rupted due to invalid parameters)
X1.4
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH
(max 125mA)
X1.5
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH
(max 125mA)
X1.6
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH
(max 125mA)
X1.7
24V_ENABLE_A
Output power
supply
Auxiliary 24V DC power supply available for EXT_ENABLE_A (max
125mA)
X1.8
EXT_ENABLE_A
Digital Input
Primary external ENABLE signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
X1.9
BUSY
Digital Output
PNP/NPN
configurable
This signal is used to know if the current spooler is executing (mark-
ing in progress):
- ON during marking process
X1.10
CONNECTOR_
PRESENCE
Digital Input
This signal is used to check the presence of the Command Box con-
nector:
- HIGH level: normal operation
- LOW level or disconnected: laser marker faulty
X1.11
START_MARK-
ING*
Digital Input
This signal is used to start to the marking process when a document
or a sequence is running in AUTO MODE** or WORK MODE**:
- HIGH level pulsed signal start the marking process
X1.12
EXT_KEY
Digital Input
External KEY signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
X1.13
STOP_MARKING*
Digital Input
This signal is used to stop the marking process:
- HIGH level pulsed signal stop the marking process
X1.14
RESERVED
-
DO NOT CONNECT
X1.15
RESERVED
-
DO NOT CONNECT