4.1.3 Type Code String High Power
Ordering type code frame sizes D and E
Description
Pos
Possible choice
Product group+series
1-6
FC 102
Power rating
8-10
60–750 hp [45–560 kW]
Phases
11
Three phases (T)
AC line voltage
11-12
T 4: 380–500V AC
T 7: 525–690V AC
Enclosure
13-15
E00: IP00/Chassis
C00: IP00/Chassis w/ stainless steel back channel
E0D: IP00/Chassis, D3 P37K-P75K, T7
C0D: IP00/Chassis w/ stainless steel back channel, D3 P37K-P75K, T7
E21: IP 21/ NEMA Type 1
E54: IP 54/ NEMA Type 12
E2D: IP 21/ NEMA Type 1, D1 P37K-P75K, T7
E5D: IP 54/ NEMA Type 12, D1 P37K-P75K, T7
E2M: IP 21/ NEMA Type 1 with line power shield
E5M: IP 54/ NEMA Type 12 with line power shield
RFI filter
16-17
H2: RFI filter, class A2 (standard)
H4: RFI filter class A1
1)
H6: RFI filter Maritime use
2)
Brake
18
B: Brake IGBT mounted
X: No brake IGBT
R: Regeneration terminals (E frames only)
Display
19
G: Graphical Local Control Panel LCP
N: Numerical Local Control Panel (LCP)
X: No Local Control Panel (D frames IP00 and IP 21 only)
Coating PCB
20
C: Coated PCB
X. No coated PCB (D frames 380–480/500V only)
Line power option
21
X: No AC line option
3: Line power disconnect and fuse
5: Line power disconnect, fuse and load sharing
7: Fuse
A: Fuse and load sharing
D: Load sharing
Adaptation
22
Reserved
Adaptation
23
Reserved
Software release
24-27
Current software
Software language
28
A options
29-30
AX: No options
A0: MCA 101 Profibus DP V1
A4: MCA 104 DeviceNet
B options
31-32
BX: No option
BK: MCB 101 General purpose I/O option
BP: MCB 105 Relay option
BO: MCB 109 Analog I/O option
B2: MCB 112 PTC Thermistor Card
B4: MCB 114 Sensor input option
C
0
options
33-34
CX: No options
C1 options
35
X: No options
C option software
36-37
XX: Standard software
How to Order
VLT
®
HVAC Drive Design Guide
MG11BB22 - VLT
®
is a registered Danfoss trademark
4-3
4
4