130B
T102.10
Figure 9.8 Permanent Magnet (PM) Motor with Resolver as
Speed Feedback
Set-up example
In
, a permanent magnet (PM) Motor is used with
resolver as speed feedback. A PM motor must usually
operate in flux mode.
Wiring
The max cable length is 500 ft [150 m] when a twisted-pair
cable is used.
NOTICE!
Always use shielded motor cables and brake chopper
cables. Resolver cables must be shielded and separated
from the motor cables. The shield of the resolver cable
must be correctly connected to the de-coupling plate,
and connected to chassis (ground) on the motor side.
Options and Accessories
Design Guide
MG34S222
Danfoss A/S © Rev. 2014-02-10 All rights reserved.