background image

6-54

Terminal

 42

 Output

 Timeout

 Preset

6-55

Analog

 Output

 Filter

6-

6*

A

na

lo

g

 O

ut

pu

X3

0/

8

6-60

Terminal

 X30/8

 Output

6-61

Terminal

 X30/8

 Min.

 Scale

6-62

Terminal

 X30/8

 Max.

 Scale

6-63

Terminal

 X30/8

 Output

 Bus

 Control

6-64

Terminal

 X30/8

 Output

 Timeout

Preset

8-

**

Co

m

m

. a

nd

 O

pt

io

ns

8-

0*

G

en

er

al

 S

et

tin

gs

8-01

Control

 Site

8-02

Control

 Source

8-03

Control

 Timeout

 Time

8-04

Control

 Timeout

 Function

8-05

End-of-Timeout

 Function

8-06

Reset

 Control

 Timeout

8-07

Diagnosis

 Trigger

8-08

Readout

 Filtering

8-09

Communication

 Charset

8-

1*

Co

nt

ro

l S

et

tin

gs

8-10

Control

 Profile

8-13

Configurable

 Status

 Word

 STW

8-

3*

FC

 P

or

Se

tt

in

gs

8-30

Protocol

8-31

Address

8-32

Baud

 Rate

8-33

Parity

 /

 Stop

 Bits

8-34

Estimated

 cycle

 time

8-35

Minimum

 Response

 Delay

8-36

Maximum

 Response

 Delay

8-37

Maximum

 Inter-Char

 Delay

8-

4*

FC

 M

C

 p

ro

to

co

l s

et

8-40

Telegram

 Selection

8-42

PCD

 write

 configuration

8-43

PCD

 read

 configuration

8-

5*

D

ig

ita

l/B

us

8-50

Coasting

 Select

8-52

DC

 Brake

 Select

8-53

Start

 Select

8-54

Reversing

 Select

8-55

Set-up

 Select

8-56

Preset

 Reference

 Select

8-

7*

BA

Cn

et

8-70

BACnet

 Device

 Instance

8-72

MS/TP

 Max

 Masters

8-73

MS/TP

 Max

 Info

 Frames

8-74

“I-Am”

 Service

8-75

Initialization

 Password

8-

8*

FC

 P

or

D

ia

gn

os

tic

s

8-80

Bus

 Message

 Count

8-81

Bus

 Error

 Count

8-82

Slave

 Messages

 Rcvd

8-83

Slave

 Error

 Count

8-84

Slave

 Messages

 Sent

8-85

Slave

 Timeout

 Errors

8-89

Diagnostics

 Count

8-

9*

Bu

Jo

g

 /

 F

ee

db

ac

k

8-90

Bus

 Jog

 1

 Speed

8-91

Bus

 Jog

 2

 Speed

8-94

Bus

 Feedback

 1

8-95

Bus

 Feedback

 2

8-96

Bus

 Feedback

 3

9-

**

Pr

of

ib

us

9-00

Setpoint

9-07

Actual

 Value

9-15

PCD

 Write

 Configuration

9-16

PCD

 Read

 Configuration

9-18

Node

 Address

9-22

Telegram

 Selection

9-23

Parameters

 for

 Signals

9-27

Parameter

 Edit

9-28

Process

 Control

9-44

Fault

 Message

 Counter

9-45

Fault

 Code

9-47

Fault

 Number

9-52

Fault

 Situation

 Counter

9-53

Profibus

 Warning

 Word

9-63

Actual

 Baud

 Rate

9-64

Device

 Identification

9-65

Profile

 Number

9-67

Control

 Word

 1

9-68

Status

 Word

 1

9-71

Profibus

 Save

 Data

 Values

9-72

ProfibusDriveReset

9-75

DO

 Identification

9-80

Defined

 Parameters

 (1)

9-81

Defined

 Parameters

 (2)

9-82

Defined

 Parameters

 (3)

9-83

Defined

 Parameters

 (4)

9-84

Defined

 Parameters

 (5)

9-90

Changed

 Parameters

 (1)

9-91

Changed

 Parameters

 (2)

9-92

Changed

 Parameters

 (3)

9-93

Changed

 Parameters

 (4)

9-94

Changed

 Parameters

 (5)

9-99

Profibus

 Revision

 Counter

10

-*

*

CA

N

 F

ie

ld

bu

s

10

-0

*

Co

m

m

on

 S

et

tin

gs

10-00

CAN

 Protocol

10-01

Baud

 Rate

 Select

10-02

MAC

 ID

10-05

Readout

 Transmit

 Error

 Counter

10-06

Readout

 Receive

 Error

 Counter

10-07

Readout

 Bus

 Off

 Counter

10

-1

*

D

ev

ic

eN

et

10-10

Process

 Data

 Type

 Selection

10-11

Process

 Data

 Config

 Write

10-12

Process

 Data

 Config

 Read

10-13

Warning

 Parameter

10-14

Net

 Reference

10-15

Net

 Control

10

-2

*

CO

Fi

lte

rs

10-20

COS

 Filter

 1

10-21

COS

 Filter

 2

10-22

COS

 Filter

 3

10-23

COS

 Filter

 4

10

-3

*

Pa

ra

m

et

er

 A

cc

es

s

10-30

Array

 Index

10-31

Store

 Data

 Values

10-32

Devicenet

 Revision

10-33

Store

 Always

10-34

DeviceNet

 Product

 Code

10-39

Devicenet

 F

 Parameters

11

-*

*

Lo

nW

or

ks

11

-0

*

Lo

nW

or

ks

 ID

11-00

Neuron

 ID

11

-1

*

LO

N

 F

un

ct

io

ns

11-10

Drive

 Profile

11-15

LON

 Warning

 Word

11-17

XIF

 Revision

11-18

LonWorks

 Revision

11

-2

*

LO

N

 P

ar

am

. A

cc

es

s

11-21

Store

 Data

 Values

12

-*

*

Et

he

rn

et

12

-0

*

IP

 S

et

tin

gs

12-00

IP

 Address

 Assignment

12-01

IP

 Address

12-02

Subnet

 Mask

12-03

Default

 Gateway

12-04

DHCP

 Server

12-05

Lease

 Expires

12-06

Name

 Servers

12-07

Domain

 Name

12-08

Host

 Name

12-09

Physical

 Address

12

-1

*

Et

he

rn

et

 L

in

Pa

ra

m

et

er

s

12-10

Link

 Status

12-11

Link

 Duration

12-12

Auto

 Negotiation

12-13

Link

 Speed

12-14

Link

 Duplex

12

-2

*

Pr

oc

es

D

at

a

12-20

Control

 Instance

12-21

Process

 Data

 Config

 Write

12-22

Process

 Data

 Config

 Read

12-27

Primary

 Master

12-28

Store

 Data

 Values

12-29

Store

 Always

12

-3

*

Et

he

rN

et

/IP

12-30

Warning

 Parameter

12-31

Net

 Reference

12-32

Net

 Control

12-33

CIP

 Revision

12-34

CIP

 Product

 Code

12-35

EDS

 Parameter

12-37

COS

 Inhibit

 Timer

12-38

COS

 Filter

12

-4

*

M

od

bu

TC

P

12-40

Status

 Parameter

12-41

Slave

 Message

 Count

12-42

Slave

 Exception

 Message

 Count

12

-8

*

O

th

er

 E

th

er

ne

Se

rv

ic

es

12-80

FTP

 Server

12-81

HTTP

 Server

12-82

SMTP

 Service

12-89

Transparent

 Socket

 Channel

 Port

12

-9

*

A

dv

an

ce

d

 E

th

er

ne

Se

rv

ic

es

12-90

Cable

 Diagnostic

12-91

Auto

 Cross

 Over

12-92

IGMP

 Snooping

12-93

Cable

 Error

 Length

12-94

Broadcast

 Storm

 Protection

12-95

Broadcast

 Storm

 Filter

12-96

Port

 Config

12-98

Interface

 Counters

12-99

Media

 Counters

13

-*

*

Sm

ar

Lo

gi

c

13

-0

*

SL

C

 S

et

tin

gs

13-00

SL

 Controller

 Mode

13-01

Start

 Event

13-02

Stop

 Event

13-03

Reset

 SLC

13

-1

*

Co

m

pa

ra

to

rs

13-10

Comparator

 Operand

13-11

Comparator

 Operator

13-12

Comparator

 Value

13

-2

*

Ti

m

er

s

13-20

SL

 Controller

 Timer

13

-4

*

Lo

gi

Ru

le

s

13-40

Logic

 Rule

 Boolean

 1

13-41

Logic

 Rule

 Operator

 1

13-42

Logic

 Rule

 Boolean

 2

13-43

Logic

 Rule

 Operator

 2

13-44

Logic

 Rule

 Boolean

 3

13

-5

*

St

at

es

13-51

SL

 Controller

 Event

13-52

SL

 Controller

 Action

14

-*

*

Sp

ec

ia

l F

un

ct

io

ns

14

-0

*

In

ve

rt

er

 S

w

itc

hi

ng

14-00

Switching

 Pattern

14-01

Switching

 Frequency

14-03

Overmodulation

14-04

PWM

 Random

14

-1

*

M

ai

ns

 O

n/

O

ff

14-10

Line

 Failure

14-11

Mains

 Voltage

 at

 Mains

 Fault

14-12

Function

 at

 Mains

 Imbalance

14

-2

*

Re

se

Fu

nc

tio

ns

14-20

Reset

 Mode

14-21

Automatic

 Restart

 Time

14-22

Operation

 Mode

14-23

Typecode

 Setting

14-25

Trip

 Delay

 at

 Torque

 Limit

14-26

Trip

 Delay

 at

 Inverter

 Fault

14-28

Production

 Settings

14-29

Service

 Code

14

-3

*

Cu

rr

en

Li

m

it

 C

tr

l.

14-30

Current

 Lim

 Ctrl,

 Proportional

 Gain

14-31

Current

 Lim

 Ctrl,

 Integration

 Time

14-32

Current

 Lim

 Ctrl,

 Filter

 Time

14

-4

*

En

er

gy

 O

pt

im

iz

in

g

14-40

VT

 Level

14-41

AEO

 Minimum

 Magnetization

14-42

Minimum

 AEO

 Frequency

14-43

Motor

 Cos

 Phi

14

-5

*

En

vi

ro

nm

en

t

14-50

RFI

 Filter

14-51

DC

 Link

 Compensation

14-52

Fan

 Control

14-53

Fan

 Monitor

14-55

Output

 Filter

14-59

Actual

 Number

 of

 Inverter

 Units

14

-6

*

A

ut

o

 D

er

at

e

14-60

Function

 at

 Over

 Temperature

14-61

Function

 at

 Inverter

 Overload

14-62

Inv.

 Overload

 Derate

 Current

15

-*

*

D

riv

In

fo

rm

at

io

n

15

-0

*

O

pe

ra

tin

g

 D

at

a

15-00

Operating

 Hours

15-01

Running

 Hours

15-02

kWh

 Counter

15-03

Power-ups

15-04

Over

 Temps

15-05

Over

 Volts

15-06

Reset

 kWh

 Counter

15-07

Reset

 Running

 Hours

 Counter

15-08

Number

 of

 Starts

15

-1

*

D

at

Lo

g

 S

et

tin

gs

15-10

Logging

 Source

15-11

Logging

 Interval

15-12

Trigger

 Event

15-13

Logging

 Mode

15-14

Samples

 Before

 Trigger

15

-2

*

H

is

to

ric

 L

og

15-20

Historic

 Log:

 Event

15-21

Historic

 Log:

 Value

15-22

Historic

 Log:

 Time

15-23

Historic

 Log:

 Date

 and

 Time

15

-3

*

A

la

rm

 L

og

15-30

Alarm

 Log:

 Error

 Code

15-31

Alarm

 Log:

 Value

15-32

Alarm

 Log:

 Time

15-33

Alarm

 Log:

 Date

 and

 Time

15

-4

*

D

riv

Id

en

tif

ic

at

io

n

15-40

FC

 Type

15-41

Power

 Section

15-42

Voltage

15-43

Software

 Version

15-44

Ordered

 Typecode

 String

15-45

Actual

 Typecode

 String

15-46

Adj

 Freq

 Dr

 Ordering

 No.

15-47

Power

 Card

 Ordering

 No.

15-48

LCP

 ID

 Num.

15-49

SW

 ID

 Control

 Card

15-50

SW

 ID

 Power

 Card

15-51

Adj

 Freq

 Dr

 Serial

 No.

15-53

Power

 Card

 Serial

 Number

15-55

Vendor

 URL

15-56

Vendor

 Name

15-59

CSIV

 Filename

15

-6

*

O

pt

io

n

 Id

en

t

15-60

Option

 Mounted

15-61

Option

 SW

 Version

15-62

Option

 Ordering

 No

About Adjustable Frequency ...

VLT

p

 HVAC Drive Instruction Manual

5-8

MG11AH22 - VLT

p

 is a registered Danfoss trademark

5

5

44

177R0521-VLT_Aqua_Drive_Training_Handout_BODY.indd   44

4/29/15   2:48 PM

Summary of Contents for vlt aqua

Page 1: ...VLT AQUA Drive Training Session Hand Outs www danfossdrives com...

Page 2: ...practice to set them up when commissioning a drive They are labeled Display Line 1 1 Small P 0 20 Display Line 1 2 Small P 0 21 Display Line 1 3 Small P 0 22 Display Line 2 Large P 0 23 and Display Li...

Page 3: ...can be viewed temporarily using the given Data Readout parameters or set up on the display permanently in the Operation Display 0 20 menu group 2 177R0521 VLT_Aqua_Drive_Training_Handout_BODY indd 2...

Page 4: ...inputs or serial communication Off means the drive is not able to run in either mode The second middle word states where the drives reference comes from The two choices are Local and Remote Local mean...

Page 5: ...cted in par 1 29 Automatic Motor Adaptation AMA The Automatic Motor Adaptation is ready to start Press Hand On on the LCP to start AMA running Enable complete or reduced AMA was selected in par 1 29 A...

Page 6: ...ith Ctrl Ramp down was selected in par 14 10 Mains Failure The Mains Voltage is below the value set in par 14 11 Mains Voltage at Mains Fault The FC ramps down the motor using a controlled ramp down C...

Page 7: ...tarily given speed is saved 1 Freeze output was selected as a function for a digital input Group 5 1 The corresponding terminal is active Speed control is only possible via the terminal functions Spee...

Page 8: ...ted in par 2 17 Over voltage Control The connected Motor is supplying the FC with generative energy The Over Voltage Control is adjusting the U f ratio to run the motor in controlled mode and to preve...

Page 9: ...he maximum reference is outside this range Sleep Boost FC 100 200 only The boost function in parameter 406Boost setpoint is enabled This function is only possible in Closed loop operation Sleep Mode F...

Page 10: ...Stop Off was pressed on the LCP or Stop inverse was selected as a function for a digital input Group 5 1 The corresponding terminal is not active Trip An alarm occurred It is possible provided the ca...

Page 11: ...ls 81 82 Digital Inputs 18 19 27 29 32 33 Digital Outputs 27 29 Analog Inputs 53 54 Analog Output 42 Control Power Supplies 24 volt supply on terminals 12 13 10 volt supply on terminal 50 Power supply...

Page 12: ...11 177R0521 VLT_Aqua_Drive_Training_Handout_BODY indd 11 4 29 15 2 47 PM...

Page 13: ...12 177R0521 VLT_Aqua_Drive_Training_Handout_BODY indd 12 4 29 15 2 47 PM...

Page 14: ...Next you must understand the relevance of parameter 3 04 There are two available choices here Sum External Preset When Sum is selected any terminal programmed as a reference resource including digita...

Page 15: ...resources but not actually used any electrical noise that might ride on those terminals will be summed into the equation After the reference sources have been defined the next step is to scale them Th...

Page 16: ...40 Relay Function Wire the VFD start contact between terminals 12 and 18 Wire the relays for VFD fault status P 5 40 sets function of relay Wire the speed reference on terminals 53 and 55 on 53 commo...

Page 17: ...se the 12 parameter quick setup menu to set up the basic parameters required for local control Behavioural Objectives Learn how to access the FC 202 s software quick menus Program understand the 12 Qu...

Page 18: ...multaneously hold down the status main menu OK keys Apply power and continue to hold the buttons for at least 5 seconds after you apply power to the drive If you were successful the display will read...

Page 19: ...not at the commanded reference speed This is because the drive is being commanded to run at 0 Hz locally but the drive will is running at 20 Hz because of the programmed low speed limit A different m...

Page 20: ...The drive will receive the control signals by means of a SCADA system The SCADA system will provide the VFD with an enable safety signal a start stop command and the 0 10 volt speed reference The dri...

Page 21: ...to answer the following questions You can refer to your documentation if necessary Which terminals should the input voltage be connected to ____ ____ ____ Which terminals should the motor be connecte...

Page 22: ...tal inputs for activation You will use a potentiometer located in the control the box and the drives onboard 10 VDC supply to create a signal that will range from 0 10 VDC This analog voltage signal w...

Page 23: ...r 5 12 automatically changes from the function Coast Inverse to External Interlock when you change P 0 03 to North America Go to parameter 5 12 and set it back to Coast Inverse then you can press the...

Page 24: ...out different voltages and frequencies to the connected motor in order to gather advanced motor data Set this parameter to the value Enable Complete AMA Press the Hand On button You will notice that...

Page 25: ...ike 0 volts to represent 0 Hz and 10 volts to represent 60 Hz Use the chart below to help you set this up These are default settings after changing parameter 0 02 to North America Potentiometer 1 AI53...

Page 26: ...emote coast With switch S3 wired to DI 27 is closed the display reads auto remote standby Closing the switch S1 wired to DI 18 starts the drive opening it stops the drive The drive runs at 20 Hz with...

Page 27: ...rive will receive the start stop signals by means of a SCADA system The VFD will have one relay output programmed to indicate when it is running at set point pressure A normally closed over pressure s...

Page 28: ...es S1 S6 to apply 24 VDC to the drives digital inputs for activation In order for the VLT AQUA drive to run in a closed loop configuration it must have a pressure transducer wired directly to it This...

Page 29: ...erlock Close the switch wired to DI 27 S3 and the alarm can be reset The drive will trip any time this switch opens simulating a safety situation or system problem Use the Quick Menu button and then e...

Page 30: ...ameters 6 20 6 21 6 24 6 25 are used scale the feedback terminal to match the feedback transducer For this lab we will be using a potentiometer to simulate a feedback signal With the use of the drives...

Page 31: ...same value as parameter 4 12 __________________________________________________________________________ 20 21 80 PSI this is our desired system set point to maintain between 3 02 3 03 20 93 2 higher...

Page 32: ...You noticed earlier that the drive would only slow to 20 Hz when running The only reason it slows to the programmed minimum speed is because the feedback is above the set point An example of where thi...

Page 33: ...ntil the PID Start Speed the drive will follow its normal ramp time Once it reaches the PID Start Speed it will start looking at the feedback and regulating pressure When the pump is commanded to stop...

Page 34: ...z 3 88 Final Ramp 1 second 20 83 PID Start Speed 60Hz In a real application the PID start speed should be set at the point where the system starts making pressure For this lab it will be set to 60 Hz...

Page 35: ...The run command will be issued internally by the RTC and the sprinkler valves will be controlled with the control cards digital outputs 27 29 When the clock is set there will be time stamps on any al...

Page 36: ...C Learn to use MCT 10 software wizards Enhance your knowledge of the VLT AQUA Drives capabilities Mechanical Setup Use the banana plugs to make the connections shown below Identify the terminals as yo...

Page 37: ...e following parameters to the values shown below 501 Output 502 Output 530 SL digital output a 531 SL digital output b 540 Relay 1 540 0 Running No Warning MCT 10 has several different wizards to assi...

Page 38: ...ve made the changes Note the actual time first and set these events to occur about five minutes from now so when the time passes the events will occur Verifying Operation 9 View the display and watch...

Page 39: ...drive A USB cable can later be connected to the drive and the program can be downloaded Existing VFD programming can also be uploaded and saved as projects within MCT 10 In addition the software cont...

Page 40: ...ides in x Double click the actual parameter of interest under setup 1 and use the drop down menus to make your selection x Click the OK button to accept the change Saving opening a project file SSP Wh...

Page 41: ...wait until the software detects it You will see USB appear under the network column Click the and you will see the connected drive which can now be programmed on the fly Reading from a drive Drives t...

Page 42: ...have not been discussed Take some time to explore the software and uncover some useful features on your own Right clicking will often bring up other available options including comparisons scope trac...

Page 43: ...ameter group is used for configuring the closed loop PID Con troller that controls the output frequency of the unit 21 Extended Closed loop Parameters for configuring the three extended closed loop PI...

Page 44: ...p down Time 3 8 Other Ramps 3 80 Jog Ramp Time 3 81 Quick Stop Ramp Time 3 82 Starting Ramp up Time 3 9 Digital Pot Meter 3 90 Step Size 3 91 Ramp Time 3 92 Power Restore 3 93 Maximum Limit 3 94 Minim...

Page 45: ...n 12 12 Auto Negotiation 12 13 Link Speed 12 14 Link Duplex 12 2 Process Data 12 20 Control Instance 12 21 Process Data Config Write 12 22 Process Data Config Read 12 27 Primary Master 12 28 Store Dat...

Page 46: ...D Start Speed RPM 20 83 PID Start Speed Hz 20 84 On Reference Bandwidth 20 9 PID Controller 20 91 PID Anti Windup 20 93 PID Proportional Gain 20 94 PID Integral Time 20 95 PID Differentiation Time 20...

Page 47: ...erm X42 3 High Ref Feedb Value 26 26 Term X42 3 Filter Time Constant 26 27 Term X42 3 Live Zero 26 3 Analog Input X42 5 26 30 Terminal X42 5 Low Voltage 26 31 Terminal X42 5 High Voltage 26 34 Term X4...

Page 48: ...ell School Road Loves Park IL 61111 USA Phone 1 800 432 6367 1 815 639 8600 Fax 1 815 639 8000 Email salesinformation danfoss com Website www danfossdrives com Danfoss VLT Drives 8800 W Bradley Road M...