Index
Name
Description
Data
Type
Range
Default
Locked
Not
Restored
65098
AnalogChannelCompensat
ion
Analogue input voltage
compensation
Enables radiometric measurement of
voltages which are proportional to
the PVED-CL 5V external reference
voltage (such as simple resistive
potentiometers).
W
Warning
Do not use for sensors which
outputs are already compensated.
U16
No
compensation (0)
0
✓
Compensation
on AD1 (1)
✓
Compensation
on AD2 (2)
✓
Compensation
on AD1+AD2 (3)
✓
65099
MaxWheelAngleLeft
Maximum wheel angle to the left
[mdeg]. Measured on
the wheel where the wheel angle
sensor is mounted
U32
[0 ; 50000]
35000
65100
MaxWheelAngleRight
Maximum wheel angle to the right
[mdeg]. Measured on
the wheel where the wheel angle
sensor is mounted
65101
SteeringWheelSensorPrese
nt
Steering wheel sensor configuration
(SASA Sensor)
BOOL
Not present: 0
Present: 255
0
Index
Name
Description
Data
Type
Range
Default
65102
HighPrioritySteeringDeviceInterface
High priority steering device
configuration
(joystick, potentiometer, other)
U8
No device connected (0)
0
Analogue device on AD1 (1)
Analogue device on AD2 (2)
CAN-based device (4)
65103
LowPrioritySteeringDeviceInterface
Low priority steering device configuration
(joystick, potentiometer, other)
No device connected (0)
Analogue device on AD1 (1)
Analogue device on AD2 (2)
CAN-based device (4)
65104
PrimaryWheelAngleSensorInterface
Steered wheel angle sensor configuration
(feedback from steered wheels)
No device connected (0)
Analogue device on AD1 (1)
Analogue device on AD2 (2)
CAN-based device (4)
65105
ExternalSetPointControllerPresent
External set-point controller configuration
(GPS)
BOOL
Not present: 0
Present: 255
65107
RedundantWheelAngleSensorPresent
Redundant steered wheel angle sensor
configuration
65108
VehicleSpeedSensorPresent
Vehicle Speed J1939 signal IO
configuration
65109
OSPPresent
Defines whether the hydraulic backup is
present.
Only on EHPS system.
65110
SpoolMonitorPresent
Valve main spool monitoring.
Monitors if main spool set-point and
actual spool position relationship.
Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Appendix
©
Danfoss | May 2016
11025583 | AQ00000216en-US0302 | 111