Index
Name
Description
Data
Type
Range
Default
Locked
Not
Restored
64002
StatusReportsPGNBase
Offset for proprietary B messages
that contains status data
U8
[0; 253]
0
64003
PvedSourceAddress
PVED-CL Source Address
19
64004
VehicleSpeedSensorSource
Address
Source Address of the vehicle speed
sensor
251
64005
ControlDeviceSourceAddre
ss
Source Address of the MMI
controller.
252
64006
ConfigurationDeviceSourc
eAddress
Source Address of the configuration/
diagnostic tool.
253
64007
HPExtSourceAddress
Source Address of the high priority
external set-point generator
28
64008
HPStdDisabledAtBootUp
High priority steering device state at
power-up
(device enable/disable)
BOOL
Enabled: 0
Disabled: 255
0
64009
LPStdDisabledAtBootUp
Low priority steering device state at
power-up
(device enable/disable)
64010
HPExtDisabledAtBootUp
High priority external set-point
controller state
at power-up (enable/disable)
64011
WAReducedModeAllowed Reduced mode switch for the wheel
angle sensor signal
Not allowed: 0
Allowed: 255
0
64012
VSReducedModeAllowed
Reduced mode switch for the vehicle
speed sensor signal
64013
HPStdReducedModeAllow
ed
Reduced mode switch for the high
priority steering device
64014
LPStdlReducedModeAllow
ed
Reduced mode switch for the low
priority steering device.
64015
HPStwPowerUpTimeout
Power-up timeout value for the
steering wheel signal
Unit: 1 ms.
U16
[100; 10 000]
100
64016
HPStdPowerUpTimeout
Power-up timeout value for the high
priority steering device set-points
(CAN) Unit: 1 ms.
64017
LPStdPowerUpTimeout
Power-up timeout value for the low
priority steering device set-points
(CAN) Unit: 1 ms.
64018
WAPowerUpTimeout
Power-up timeout value for the
wheel angle sensor
Unit: 1 ms.
U16
[60; 10 000]
60
64019
VSPowerUpTimeout
Power-up timeout value for the
vehicle speed signal
Unit: 1 ms.
[160; 10 000]
160
64020
StwDxFilterThreshold
Threshold for the steering wheel dx
filter
0,1: Disable filter
2
[2 ; 4095]
64021
StwDxFilterStartTime
Timeout-value for the steering wheel
dx filter activation
Unit: 1ms
U16
0: filter always
enabled
0
[1 ; 65515]
> 65515: Disable
filter
Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Appendix
©
Danfoss | May 2016
11025583 | AQ00000216en-US0302 | 109