VARIABLE AND COMMAND LIST
09/05
Danaher Motion
84
M-SS-017-04 Rev. M
VarCom Reference
RESBW
Set the cutoff frequency of the filter.
Syntax:
RESBW <
value
>
to set the cut-off frequency
RESBW
to read the cut-off frequency
Type:
switch mode (R/W)
Range:
300, 600, 1200
Units:
Hz
Default:
600
Opmodes:
All
Drive Status:
DIS
Firmware:
6.3.3 and higher
EEPROM:
No
RSTVAR
Sets all variables, switch variables, and switch mode variables to their
factory default settings. These settings are stated within this document
under the variable DEFAULT category. The default values of variables
loaded from a motor data file cannot be predicted and are denoted
motor data in the DEFAULT category.
Default values:
ACC = 400,000
ACKMODE = 0
ACTFAULT = 0
ANDB = 0
ANOFF = 0
ANOUT = 0
AVGTIME = 0
BW = 20
ANDG = 0
COMPFILT = 1
COMPMODE = 2
DEC = 400,000
DIR = 1
DISSPEED = 50
DISTIME = 100
ECHO = 1
ENCOUT = 1024
ENCOUTO = 1
FILTMODE = 0
FOLDMODE = 0
FOLDTIME = 30
GEAR = 1
GEARI = 1
GEARMODE = 3
GEARO = 1
GETMODE = 0
GPAFR = 0
GPAFR2 = 0
GPD = 0
GPI = 0
GPISATIN = 0
GPISATOUT = 0
GPVFR = 0
GV = 500
GVI = 20
HOMESPD = 100
HOMETYPE = 0
IENCSTART = 25 IFRIC = 0
IGRAV = 0
ILIM = IMAX
ILIM2 = 100
ILSBMODE = 2
IN1MODE = 1
IN2MODE = 2
IN3MODE = 3
ISCALE = 1250
ISTOP = DICONT
IZERO = 20
KV = 1000
KVI = 1000
KVFR = 0
LIMDIS = 0
LMJR = 0
MPFHZ1 = 500
LPFHZ2 = 500
MAPOS = 0
MASPEED = 0
MFBDIR = 0
MFOLDD = 1200
MFOLDDIS = 0
MFOLDR = 1800
MFOLDT = 600
MIDISTx = 0
MISPEEDx = 100
MSININT = 256
MPHASE = 0
MSG = 1
MSINFRQ = 1
NOTCHBW = 1
NOTCHHZ = 500
O1MODE = 6
O1RST = VOSPD
O1TRIG = 1000
OPMODE = 1
PCMDMODE = 0
PEMAX = 0
PLIM = 0
PMAX = 2,000,000,000 PMIN = 2,000,000,000
PROFMODE = 0
PROFSCRV = 50 PROMPT = 1
RELAYMODE = 0
SININTOUT = 1
STOPPED = 0
TF = 100
THERMODE = 0
THERMTIME = 30 THERMTYPE = 0 UNITS = 0
UVMODE = 0
UVTIME = 30
UVRECOVER = 0 VD = 0
VF = 1,000,000
VH = 0
VLIM = VMAX
VOSPEED = 1.2 * VLIM VR = 0
XENCDIR = 0
XENCRES = 1024
Firmware Versions:
All
Command Syntax:
RSTVAR
Opmodes:
0, 1
Drive Status:
DIS