If the rescaler is need ed , set the rescaler as show n in the follow ing figu re:
Figure 37: Rescaler
If the rescaler is enabled , the external line frequ ency w ill be m od ified u sing the Trigger Mu ltip lier and Trigger
Divid er com m an d s, as sh ow n above. For d etails, p lease refer to the Rescaler section in the GURU section.
N ote: the Trigger Mu ltip lier takes the follow ing three valu es only:
0 = frequ ency x 256
1 = frequ ency x 16
2 = frequ ency x 4096
For m ore inform ation abou t the Rescaler, p lease refer to Rescaler in the GURU section.
External Line Trigger, External Direction Control from Rotary
Encoder
Physically connect rotary En cod er p h ase A to p in 1-5 if u sing TTL, or p in 1-2 if u sing LVDS, and p h ase B to p in
6-5 if u sing TTL, or p in6-7 if u sing LVDS.
In the Line Trigger Fu nction Grou p > Set the Line Trigger Mod e valu e to On.
Set Rotary Encod er Mod u le to Tru e.
Figure 38: Rotary Encoder Module