26
Spyder3 SG-34 GigE Vision Color Manual
03-032-20124-00
Teledyne DALSA
At this p oint you are read y to start op erating the cam era in ord er to acqu ire im ages, set cam era fu nctions,
and save settings.
Camera Operation
Factory Settings
The cam era ship s and p ow ers u p for the first tim e w ith the follow ing factory settings:
Forw ard CCD shift d irection
8 bit, 2 tap
N o binning
Exp osu re m od e: internal sync & m axim u m exp osu re tim e
5, 000 H z line rate
Factory calibrated analog gain and offset
Factory calibrated FPN and PRN U coefficients
Check Camera and Sensor Information
Camera and sensor information can be retrieved via a controlling application—in the examples shown here,
CamExpert. Parameters such as camera model, firmware version, sensor characteristics, etc. are read to uniquely
identify the connected device.
The cam era inform ation p aram eters are grou p ed together as m em bers of the Cam era Inform ation set.
GigE Vision Input Controls
Camera Information
Parameter
Options
Manu factu rer N am e
Mod el N am e
Manu factu rer Info
Device Version
Device ID
Device User ID
Define a cam era nam e u p to 64 characters
Serial nu m ber
Read Voltage and
Tem p eratu re
Click to read the voltage from the cam era . In general, the tem p eratu re read is 15 C
greater than the tem p eratu re at the front p late. The tem p eratu re shou ld not exceed 80
°C.
Inp u t Voltage
Read Only Parameters