62
Spyder3 SG-34 GigE Vision Color Manual
03-032-20124-00
Teledyne DALSA
Internal Line Trigger, External Direction Control, Internal frame
trigger
Set the Fram e Start Trigger and Fram e Active Trigger valu es to off, as d escribed above. Set the Line Trigger
Mod e valu e to Off an d the Exp osu re Mod e, Exp osu re Tim e and Line Rate as above.
In the Direction Control Grou p > set the Sensor Scan Direction to External.
Set the Inp u t Direction Signal to Line 2 (as d escribed at th e start to this section ).
Figure 35: Scan Direction
External Line Trigger, Internal Direction Control, Internal frame
trigger
In the Direction Control Grou p > set the p aram eter Sensor Scan Direction > to Forw ard or Reverse, d ep en d ing
on you r ap p lication.
Set the Fram e Start Trigger and Fram e Active Trigger valu es to off, as d escribed above.
In the Line Trigger Fu nction Grou p > Set the Line Trigger Mod e valu e to On.
Figure 36: Line Trigger Mode
Set the Inp u t Direction Signal to Line 0 (as d escribed at th e start to this section ).
Verify the line frequ ency valu e by clicking the Read External Line Frequ ency p aram eter in the Line Trigger
Fu nction Grou p , as sh ow n in the figu re above.