The File Access control in CamExpert allows the user to quickly upload various data files to the
connected Genie Nano. The supported data files are for firmware updates and other types
dependent on the Nano model.
Features listed in the description table but tagged as Invisible are usually for Teledyne DALSA or
third party software usage—not typically needed by end user applications.
File Access Control Feature Descriptions
The Device Version number represents the camera firmware release number. New features for a
major device version release will be indicated by
green text
for easy identification.
Display Nam e
Feature & Values
Description
Device
Version
& View
File Selector
FileSelector
Selects the file to access. T he file types which are
ac cessible are device-dependent.
1 .0 0
Guru
Firmware
Firmware1 Upload new firmware to the camera which will
execute on the next camera reboot cycle. Select
the DeviceRes et feature after the upload
completes .
Factory Defective Pixel Map
BadPixelCoordinate0 Select the Factory Defective Pixel Map.
Us er Defective Pixel Map
BadPixelCoordinate1 Select the User Defective Pixel Map XML file as
defined in Advanced Processing.
Factory Flat Line coefficients 1
FlatFieldCoefficients01 Select factory Flat Line coefficients 1. These are
the factory values used when the camera
fas tReadoutMode is Off and s ensor Gain is 1.0.
Factory Flat Line coefficients 2
FlatFieldCoefficients02 Select factory Flat Line coefficients 2. These are
the factory values used when the camera
fas tReadoutMode is Off and s ensor Gain is 1.26.
Factory Flat Line coefficients 3
FlatFieldCoefficients03 Select factory Flat Line coefficients 3. These are
the factory values used when the camera
fas tReadoutMode is Off and s ensor Gain is 1.87.
Factory Flat Line coefficients 4
FlatFieldCoefficients04 Select factory Flat Line coefficients 4. These are
the factory values used when the camera
fas tReadoutMode is Off and s ensor Gain is 3.17.
Factory Flat Line coefficients 5
FlatFieldCoefficients05 Select factory Flat Line coefficients 5. These are
the factory values used when the camera
fas tReadoutMode is Active and s ensor Gain is 1.0.
Summary of Contents for Genie Nano-CXP Series
Page 6: ...4 Contents Genie Nano CXP Series TECHNICAL SUPPORT 104...
Page 84: ...82 Technical Specifications Genie Nano CXP Series EMC Declaration of Conformity...
Page 85: ...Genie Nano CXP Series Technical Specifications 83 EU Declaration of Conformity...
Page 86: ...84 Technical Specifications Genie Nano CXP Series Declaration of REACH...
Page 95: ...Genie Nano CXP Series Additional Reference Information 93 Cable AssemblyG3 AIOC BLUNT1M...
Page 96: ...94 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BLUNT2M...
Page 97: ...Genie Nano CXP Series Additional Reference Information 95...
Page 98: ...96 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BRKOUT2M...
Page 99: ...Genie Nano CXP Series Additional Reference Information 97...
Page 100: ...98 Additional Reference Information Genie Nano CXP Series Nano GenericPowerSupplywith no I O...
Page 107: ...Genie Nano CXP Series Contact Information 105...