Genie Nano-CXP Series™
Operational Reference
•
33
Synchronous Exposure Alignment
Exposure is synchronous to the internal timing of the sensor. The readout is concurrent to the
exposure for the fastest possible frame rate.
When a valid trigger is received and the Exposure Time is shorter than the readout period, the
Exposure Start event is latched in the previous frame’s readout. That is; the Exposure Start Event
is delayed and is initiated when the actual exposure starts such that the exposure ends and
readout begins as soon as the previous readout has completed.
•
The programmable exposure duration is in 1µs steps.
•
Exposure duration is from a camera sensor specific minimum (in µs) up to 10 sec.
•
Any trigger received before the start of frame readout is ignored and generates an invalid frame
trigger event.
Reset Exposure Alignment
Sensor timing is reset to initiate exposure when a valid trigger is received. Readout is sequential to
exposure, reducing the maximum achievable frame rates. That is, a trigger received during
exposure or readout is ignored since data would be lost by performing a reset.
Sensor Exposure Timing: OnSemi Python Models
Nano cameras with OnSemi sensors have general timing characteristics as described below.
Trigger Characteristics: Start of Exposure
External
Trigger Input
Input propagation Delay (see Input Signals Electrical Specifications)
Internal Trigger Control
<< Exposure Active >>
Start of Exposure Details
for Nano Models using OnSemi Python
rising edge active
Internal Delay (exposureAlignment = Reset or Synchronous With No Overlap)
Internal Delay (exposureAlignment = Synchronous With Overlap)
Additional triggered exposure mode features and timing specific to OnSemi sensors are described
in the
.
Summary of Contents for Genie Nano-CXP Series
Page 6: ...4 Contents Genie Nano CXP Series TECHNICAL SUPPORT 104...
Page 84: ...82 Technical Specifications Genie Nano CXP Series EMC Declaration of Conformity...
Page 85: ...Genie Nano CXP Series Technical Specifications 83 EU Declaration of Conformity...
Page 86: ...84 Technical Specifications Genie Nano CXP Series Declaration of REACH...
Page 95: ...Genie Nano CXP Series Additional Reference Information 93 Cable AssemblyG3 AIOC BLUNT1M...
Page 96: ...94 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BLUNT2M...
Page 97: ...Genie Nano CXP Series Additional Reference Information 95...
Page 98: ...96 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BRKOUT2M...
Page 99: ...Genie Nano CXP Series Additional Reference Information 97...
Page 100: ...98 Additional Reference Information Genie Nano CXP Series Nano GenericPowerSupplywith no I O...
Page 107: ...Genie Nano CXP Series Contact Information 105...