38
•
Operational Reference
Genie Nano-CXP Series™
Trigger Overlap: Feature Details
The Trigger Overlap feature defines how the Nano handles triggers that might occur more
frequently than the Frame Active period (an exposure plus readout period).
If TriggerOverlap=OFF, then triggers received before the end of the Frame Active period are
ignored. Other TriggerOverlap values are dependent on the Nano model and sensor used.
•
TriggerOverlap=Off
•
No trigger overlap is permitted.
Diagram Conditions:
•
TriggerMode=On
•
ExposureMode=Timed
•
TriggerActivation=RisingEdge
•
TriggerDelay=0
•
TriggerSelector=FrameStart
•
ExposureAlignment=Synchronous
•
Minimum Trigger to Exposure start delay: 3.23µs (shown as 4µs)
Trigger Input
Trigger Exclusion Period
Exposure 1
Readout 1
Frame 1 Active period
Trigger Exclusion Period
Exposure 2
Readout 2
Frame 2 Active period
Frame Exposure
Frame Readout
TriggerOverlap=Off
Summary of Contents for Genie Nano-CXP Series
Page 6: ...4 Contents Genie Nano CXP Series TECHNICAL SUPPORT 104...
Page 84: ...82 Technical Specifications Genie Nano CXP Series EMC Declaration of Conformity...
Page 85: ...Genie Nano CXP Series Technical Specifications 83 EU Declaration of Conformity...
Page 86: ...84 Technical Specifications Genie Nano CXP Series Declaration of REACH...
Page 95: ...Genie Nano CXP Series Additional Reference Information 93 Cable AssemblyG3 AIOC BLUNT1M...
Page 96: ...94 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BLUNT2M...
Page 97: ...Genie Nano CXP Series Additional Reference Information 95...
Page 98: ...96 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BRKOUT2M...
Page 99: ...Genie Nano CXP Series Additional Reference Information 97...
Page 100: ...98 Additional Reference Information Genie Nano CXP Series Nano GenericPowerSupplywith no I O...
Page 107: ...Genie Nano CXP Series Contact Information 105...