24
If your first correspondent does not answer the call, is already engaged or has not terminated the call cycle properly:
• the dialler calls the number recorded in the next memory,
• if none of the correspondents acknowledge or terminate the call cycle or they are all engaged or not answering, the dialler
goes through the complete call cycle.
Example: call cycle with 3 different types of cycle (intrusion, fire, fault):
Procedure
Acknowledgement
and termination
For each cycle, if the
first calls are not
acknowledged and
terminated, the dialler
continues on to the
next numbers in the
same cycle. When
one of the calls in the
cycle is
acknowledged, the
dialler stops
transmission.
Cycle 1:
number 1
number 2
number 3
Cycle 2:
number 4
number 5
Cycle 3:
number 6
number 7
number 8
3. Outgoing calls
IMPORTANT
• If the alarm control panel issues a disarm order during the cycle:
- for calls to individuals: the dialler issues the voice message “Off, Control_ panel” and immediately puts an end to
communication,
- for calls to a remote monitoring centre: the dialler terminates the call underway and transmits the “Off” order if the call is
answered.
• Your installer can be directly warned of any fault with the system, regardless of alarm transmissions.
System correspondent
A 9
th
number is programmed to be the “system correspondent” number for receiving:
• SMS messages for the
“credit monitoring”
function (if activated),
• the list of SMS (every 3 days if the system correspondent has been programmed),
• MMS images from IP cameras or detectors recognised by the control panel and the dialler (MMS parameters set),
• the date the validity of the SIM card ends (if card activated).
GSM/GPR
S
The dialler remotely alerts correspondents of intrusion or other events occurring on the protected site.
3.1 Dialler call cycle procedure