Control panel voice message
Events
“bip, date, time, intrusion, detector n°, group n°”
Intrusion on premises.
“bip, date, time, intrusion confirmed, detector n°, group n°”
Movement of the intruder on the premises.
Intrusion protection
IMPORTANT: the alarm memory is automatically deleted the next time the system is armed.
* Requires the installation of a dialler unit in the control panel or the installation of a separate dialler.
• Alarms (intrusion, personal, technical, tamper or fire) are
indicated:
- on receipt of an Off order,
- when the system is operated remotely.
• Voice indications specify:
- the date and time at which the alarm occurred,
- the type of alarm,
- the identity of the device having triggered the alarm.
7. The control panel indicates alarms
Control panel voice message
Events
“bip, bip, bip, bip, Technical Alarm, Technical Detector n°”
Message repeated every 10 seconds for 3 minutes
(except in Total Arm mode)
Technical protection triggered by a sensor associated with a universal
transmitter.
Technical protection
Control panel voice message
Events
“bip, date, time, Fire Alarm, Detector n°”
Fire protection triggered by a detector.
Fire protection
“bip, date, time, Fire Alarm, Remote Control_Unit n°”
Fire protection triggered by a remote control unit.
2
4
/2
4
Control panel voice message
Events
Protection against system tampering
“bip, date, time, Tamper, Remote Control Unit n°”
Attempt to open or remove a keypad.
“bip, date, time, Tamper, Control Panel”
Attempt to remove or open the control panel.
“bip, date, time, Tamper, Siren n°”
or
“Tamper, relay n°”
Attempt to remove a siren or radio repeater relay.
“bip, date, time, Tamper, Detector n°, Group n°”
Attempt to open or remove a detector.
“bip, date, time, Tamper, Radio”
Detection of radio scrambling.
2
4
/2
4
2