General Outline
ESIE05-04
1–10
Part 1 – System Outline
3
1
1
4
5
1.5
FCQ100, 125, 140D
Outlook and
dimensions
The illustration below shows the outlook and the dimensions of the unit (mm).
NOT
E
S
:
1.
L
o
ca
ti
on
of uni
t’
s nam
e pl
ate
fo
r
indo
or
uni
t : on
th
e b
e
ll m
outh
i
n
si
d
e
su
cti
on
gr
ill
fo
r
deco
ra
ti
on
pan
el
:
on
the
i
n
n
e
r f
ram
e
in
si
de
suct
ion
gri
ll
2.
In
case
o
f usin
g wir
ele
ss r
e
m
o
te
cont
ro
lle
r,
th
is
p
o
sitio
n will
b
e
a sign
a
l r
e
c
e
iver
.
Re
fer
to
the
dr
awing
of
wire
le
ss r
e
m
o
te
con
tro
lle
r f
o
r
deta
il.
3.
W
h
en
the t
e
m
per
atu
re a
n
d
h
u
m
idity in
the c
e
iling e
xcee
d 3
0
°C a
nd RH 8
0
%
or
the fr
esh
a
ir
is
in
du
cted
in
to th
e ceiling
o
r the
unit co
ntin
ues 2
4
hou
r op
er
a
tion
,
a
n
a
d
d
it
iona
l i
n
su
la
ti
on
(t
hi
ckne
ss 1
0
m
m
o
r m
o
re
of
gl
as
sw
ool
or
pol
ye
thyl
e
ne
fo
rm
) i
s
re
qui
red.
4.
T
h
o
u
g
h
th
e in
stalla
tion
is acce
pta
ble
up
to m
a
xim
u
m
of
910
mm
sq
uar
e ce
iling
o
p
e
n
in
g
, ke
ep t
he
cl
ear
an
ce o
f 35
mm
or
l
e
ss
be
tw
ee
n th
e m
a
in
uni
t and
th
e
c
e
ili
ng
ope
ni
n
g
so
tha
t th
e p
ane
l ove
rl
ap
al
lo
w
anc
e ca
n b
e
e
n
sur
ed
.
S
u
spension
bolt
35
o
r
le
s
s
35 or
less
(N
ote
4).
(R
equire
d space)
1500 or m
ore
Fro
m
the fl
oor si
de 2500 or
FO
R HEIGHT
IN
STA
LL
AT
IO
N
860~
910 (C
eili
ng
open
in
g s
pac
e)(N
ote
4
)
780 (
Susp
ension po
sition)
86
0~910 (
C
eiling op
ening sp
ace)
(Note 4
)
3
00
or
l
e
s
s
(N
o
te 2)
D
rai
n connect
io
n
side
P
ipe con
nection
side
*
WHEN T
H
E
DISCHARGE GRI
L
L
IS CL
OSED,
THE REQ
UI
RE
D
SP
ACE I
S
2
0
0
m
m
O
R
M
O
RE.
1500m
m
or m
o
re
*
1500
mm o
r mo
re
*
B
ranch d
u
ct
conne
ction
12-
M4 h
o
le
B ARROW
VIEW
4
-M4
hol
e
B
ran
ch duct
conn
ection
1
500m
m or
mor
e
*
150
0mm
or
mo
re
*
•
RE
QUIRE
D S
P
A
CE
B
ranch d
u
ct
conne
ction
12-
M4 h
o
le
C ARROW VIEW
D ARRO
W VIEW
Outdoo
r ai
r i
n
take
(Direct connect
io
n)
12-M
4 ho
le
12-M
4 hol
e
B
ran
ch duct
con
nection
68
0 (S
uspe
nsi
on po
si
ti
on)
Adju
stab
le
(0
~0
55
)
Summary of Contents for FCQ35B7V1
Page 1: ...Service Manual ESIE05 04 R 410A Sky Air Indoor...
Page 2: ......
Page 20: ...ESIE05 04 1 2 Part 1 System Outline 3 1 1 5...
Page 62: ...General Outline ESIE05 04 1 44 Part 1 System Outline 3 1 1 4 5...
Page 78: ...ESIE05 04 1 60 Part 1 System Outline...
Page 112: ...Wiring Diagrams ESIE05 04 1 94 Part 1 System Outline 3 1 1 4 5...
Page 140: ...ESIE05 04 2 2 Part 2 Functional Description 3 1 2 5...
Page 164: ...ESIE05 04 3 2 Part 3 Troubleshooting 3 1 3 5...
Page 206: ...Error Codes ESIE05 04 3 44 Part 3 Troubleshooting 3 1 3 4 5...
Page 224: ...Additional Checks for Troubleshooting ESIE05 04 3 62 Part 3 Troubleshooting 3 1 3 4 5...
Page 226: ...ESIE05 04 4 2 Part 4 Commissioning and Test Run 3 1 4 5...
Page 252: ...ESIE05 04 5 2 Part 5 Disassembly and Maintenance 3 1 5...
Page 384: ...Disassembly and Maintenance ESIE05 04 5 134 Part 5 Disassembly and Maintenance 3 1 5 5...
Page 390: ...ESIE05 04 vi Index 3 1 4 5 W Wiring diagrams Indoor units k 1 61...