PIM00411
12-3
Item
Sign
Name
Operating range
Default
setting
Description
Reference
surge pressure is more likely to occur.
In addition, if set to 0, the acceleration
response gain will become the maximum
that is defined by the controller. And the
acceleration time will become the
minimum.
P12 W_TM
Solenoid valve
response delay
time
0.00
~
9.99[sec]
0
After switching the PQ pattern, it will
change the pressure command or the flow
rate command after a delay determined
by this parameter.
Please adjust it, if you want to change
pressure or flow rate, and avoid the
instability in switching solenoid valve.
12-13
PQ selection number 0 ~ 15
MPa
PL.0
~
PL.F
Low-pressure side
pressure setting
×10PSI
Setting the target pressure.
qL.0
~
qL.F
Low-pressure side
flow rate setting
L/min
Setting the target flow rate (theoretical).
Make sure the setting value does not
exceed the low pressure side flow setting.
Ut.0
~
Ut.F
Acceleration time
setting
0.01
~
99.99
[sec/MPa]
[sec/1000min
-1
]
Setting the change time, when the
pressure command or flow rate command
is increased at the time of switching the
PQ pattern.
・
Pressure command: Increase 1MPa
time.
・
Flow rate command: Increase
1000min-1 time.
-P13
~
P28
dt.0
~
dt.F
Deceleration time
setting
0.01
~
99.99
[sec/MPa]
[sec/1000min
-1
]
Please
refer to
12-5
Table 2
Setting the change time, when the
pressure command or flow rate command
is decreased at the time of switching the
PQ pattern.
・
Pressure command: Decrease 1MPa
time.
・
Flow rate command: Decrease
1000min-1 time.
12-6
P29 C_TM
Unused setting
items
-
-
It does not affect the function, but please
do not change the setting.
-
P30 DF_N
Unused setting
items
-
-
It does not affect the function, but please
do not change the setting.
-
P31
P_SN
Pressure sensor
ratings
1
~
35[MPa]
10
Setting the rated pressure of the pressure
sensor.
Usually it is not necessary to change the
settings.
-
P32 S_TM
Surge less start-up
time
0.01
~
9.99[sec]
0.5
Setting the start-up time from the motor
stop to start-up.
Increasing the value can prevent the
rising surge. But the response time of
start-up will be longer.
12-13
P33
L_IN
Motor start initial
response gain
1
~
999
10
Setting the output of the motor at the time
of start-up.
Decreasing the value can prevent the
rising surge. But the response time of
start-up will be longer.
12-13