PIM00411
11-2
11.2.2
Mode switching operation
Switching among these modes as shown in figure below. Please refer to the description of each mode for details of
operation.
Monitor mode
Setting Mode
Alarm Mode
Normal mode
Press the
key at the same time
for 2 seconds.
Press the
key at the same time
for 2 seconds.
Power ON
11.3
Normal mode
In normal mode, the panel display different content in different state as shown in the table below.
Status
Panel display
Remarks
Power is turned on
All LED will flash momentarily when the power is turned on.
Normal
Display the current pressure in the normal status.
Stop
Under the stop command, and the pressure is 0.15MPa or less.
AC fail
Flash in the AC fail status.
Alarm or warning
occurs
When alarm or warning occurs, display the alarm code or
warning code.