PIM00411
7-2
DANGER
If other parts (such as pump pipe) besides the long hooking hole are used to hook, there is a risk of falling or
collapse.
Check the weight of the hydraulic unit in the above table, please make sure it is under the lift rated load.
WARNING
During the transportation, must equally hook at four points of the long hooking hole.
During transportation by sling, please do not stay too near. There is a risk of injury due to falling.
CAUTION
Avoid transporting the hydraulic unit with hydraulic oil contained in the tank. This may cause oil leak, or
malfunction due to air intrusion.
This product is a precision instrument. Please do not shock or drop it. It may be damaged.
During the transportation , please do not touch the harness, piping, and solenoid valve. There is a risk of
accidents caused by falling or damage.
Fix and make sure it can not be moved by external force or vibration during the transportation.
7.2
Installation
7.2.1
Ensuring air intake/exhaust space
Install this unit at well-ventilated place without hot air, and keep space 10 cm from the unit end surface. Make sure
that the intake air temperature does not exceed the specified ambient temperature range (40
°
C or lower
temperature).
Exhaust
10 cm or more
10 cm or more
Air
intake
WARNING
If the intake / exhaust space above can not be ensured, the heat exchange efficience of the oil cooler / AC
fan will be reduced. There is a risk of burns because the hydraulic oil and equipment will become
extremely hot.
So, please keep the intake / exhaust space as shown in the figure above.
If you accidentally touch the hot parts, you may get burns.