Output signal Setting
The digital output, and the signal type can be selected by parameters, as shown in the table below.
12.4.1
Parameter
■
Parameters for output signal
Display
Sign
Parameter Name
Range
Factory Default
Setting
Unit
P07
WN_M
Warning output level
0
~
2
0
-
P08
AMIX
Alarm output mix
0
~
2
1
-
P39
DO_S
Digital output selection
0
~
7
0
-
12.4.2
[P39: DO_S] Digital output selection
By changing the parameter "P39: Digital output selection ", the function of digital output DO1 can be selected.
■
Digital output DO1 selection
P39: Digital output selection
Function
Description
0
PQ number switching
completion output
When switch the PQ selection number, if the pressure
command, flow rate command reach the goal, it will
become ON.
1
Motor running output
It will become ON when the motor power is on.
2
High-pressure side
running output
It will become ON, if only the high pressure side runs.
3
(Reserved for system)
(Reserved for system)
4
Pressure and flow
coincidence output
It will become ON, when the flow rate or pressure
match.
5
Pressure coincidence
output
It will become ON , when the pressure matches.
6
Flow rate coincidence
output
It will become ON , when the flow rate matches.
7
Fully charged Output
It will become ON, if the main circuit is charged fully.
■
Pressure coincidence / Flow rate coincidence detection
The current pressure and flow rate can be detected, when the pressure or flow rate command value is within a
certain range.
The coincidence detection range, by setting a percentage of the command value, is limited by the coincidence
detection minimum.
No.
Sign
Name
Range
Factory Default
Setting
Unit
P41
PCMW
Pressure coincidence
detection range
0
~
99
5
%
P42
PCMM
The minimum value of
pressure coincidence
detection
0.0
~
99.9
0.1
MPa
P43
QCMW
Flow rate coincidence
detection range
0
~
99
5
%
P44
QCMM
The minimum value of
flow rate coincidence
detection
0.0
~
99.9
0.2
L/min