FL 500 XT B

LED light generators
for use with fibre optic lighting

User manual

Mounting and installation instructions   

Item no.:    

0121 0211     FL 500 XT B Ø9 3000K

                   

 

+99082113

  15.04.2015

Summary of Contents for FL 500 XT B

Page 1: ...FL 500 XT B LED light generators for use with fibre optic lighting User manual Mounting and installation instructions Item no 0121 0211 FL 500 XT B Ø9 3000K 99082113 15 04 2015 ...

Page 2: ...roubleshooting 1 Introduction Roblon FL 500 light generators are designed for use outdoors with glass or PMMA fibre in cabinets or showcases either in closed or semi closed compartments Follow the installation instructions correctly in order to ensure safe operation enhanced functionality extended lifetime for components uninterrupted illumination ...

Page 3: ...2 Product overview FL 500 XT B light generator User manual ...

Page 4: ...lifetime 25 000 hours CCT nominal 3 000 K CRI8 Ra typical value 90 Protection rating IP 65 Driver type Electronic Driver lifetime 25 000 hours Dimmable Yes Thermal protection Integrated auto Cooling system Natural convection Noise level N a Ambient temperature 20 C to 40 C Material Aluminium Dimensions L x H x W 164 x 67 x 63 mm Weight 600 g Safety CE F ...

Page 5: ...d of the light generator 2 Insert the common end fully in the light port 3 Tighten the screw on the light port 4 Mount the plug again Ensure all installation and ventilation requirements are met and connect the supply cord to the mains 1 2 3 4 ...

Page 6: ...ce to allow natural heat transmission through surfaces Surfaces should not be insulated Air volume per light generator minimum 0 03 m Ventilation holes per light generator with min 20 cm air inlet and min 20 cm air outlet Inlet and outlet ventilation holes opposite each other Max ambient temperature 40ºC Measuring temperature see Troubleshooting 84 mm ...

Page 7: ...tor too hot Check it is installed according to the instructions Let it cool for 10 minutes Try again Is the LED old Replace the LED Light output has diminished Is the light generator too hot Check it is installed according to the instructions Let it cool for 10 minutes Try again Is the harness common end dirty Clean harness common end with a damp cloth Dry with lint free cloth Ambient temperature ...

Page 8: ...ax 45 9620 3399 9900 Frederikshavn info roblon com Denmark www roblon com Roblon accepts no responsibility for possible errors in printed and electronic material Roblon reserves the right to alter or discontinue products without notice 2012 Roblon A S ...