PIM00411
14-1
Chapter 14
Output Signal Timing Chart
About the start-stop signal (digital input 0), the setting value of [P11: start-stop signal switching] is "1" (default).
If the setting value of [P11: start-stop signal switching] is changed to "0", the ON and OFF of the start-stop signal
(digital input 0) will be inverted.
14.1
Timing chart when the power is turned on
14.1.1
When the setting value of "P08: Alarm output mix" is "0" or "2"
detection(*1)
DIN1
(Start-Stop
Signal)
Power
(200V)
Charge
Normal status
At most 3sec
OFF:Operation commnad
ON:Stop commnad
OFF
ON
Actual pressure
Unit operation
Display
DO2
(Total output)
Digital
input
Digital
output
Magnetic pole
Operation
waiting
0.2sec
on average
14.1.2
When the setting value of "P08: Alarm output mix" is "1"
Actual pressure
Normal status
Magnetic pole
Operation
Charge
At most 3sec
ON:Stop commnad
OFF:Operation commnad
Power
(200V)
OFF
ON
Unit operation
Display
(Start-Stop
Signal)
DIN1
AL_A
(
:Integrated output
)
Digital
input
Digital
output
waiting
0.2sec
on average
detection(*1)
*1 Magnetic pole detection is performed only when the motor start at the first time after turning on the power.