PIM00411
12-14
Time
Pressure
command
0
P32: Surge less start-up time – 100[ms]
Pressure setting in high
pressure side
■
Co mmand at unit start, and change of motor output
Time
Flow rate
command
0
P32: Surge less start-up time – 100[ms]
Flow rate setting in
high pressure side
Time
M otor output
0
[P32: Surge less start-up time – 100[ms]
P33:Motor start initia l
response gain
12.6.3
[P45: AC_F] AC fan start-stop signal synchronization settings
It is possible to start / stop the AC fan in synchronism with the pump start / stop signal by “DIN1: Start-stop signal”.
The power consumption and noise when the pump is stopped can be reduced.
Display Sign
Parameter name
Range
Factory
Default
Setting
Description
Reference
P45
AC_F
AC fan motor
synchronization
0: Always operation
1: Synchronized
operation
0
It can start / stop the AC fan in
synchronization with the start /
stop signal.
―
Note
If the AC fan stops, the motor temperature will rise. If start the AC fan again, it will not be a
malfunction.