![background image](http://html.mh-extra.com/html/daikin/ary20dv2/ary20dv2_service-manual_501356085.webp)
Indoor Unit
SiBE01-503
76
Removal Procedure
2. Remove the front grille
assembly.
1
Remove the two
screws, in the right and
the left, which fix the
main body with the front
grille.
Screw stoppers inside the
flap which were equipped in
the existing models are not
provided.
2
Disengage the two
hooks on the upper
part.
In case that the hooks
are not pressed from
above, remove the front
panel and then remove
the grille while pushing
the hook through a
clearance between the
front grille and the heat
exchanger.
At the upper part there are
two hooks in the left and the
right.
Disengage the hooks by
pressing knobs with a
screwdriver.
Step
Procedure
Points