background image

OPERATING MANUAL

 

AIR CLEANER

TAC 1500  /  TAC 3000

EN

TR

T-BA-

TA

C1500_3000T

C-004-EN

Summary of Contents for TAC 1500

Page 1: ...OPERATING MANUAL AIR CLEANER TAC 1500 TAC 3000 EN TRT BA TAC1500_3000TC 004 EN...

Page 2: ...ges to construction in the interests of constant improve ments to the product as well as changes to the shape and colour are reserved The scope of delivery may vary from product images This docu ment...

Page 3: ...sing during the above mentioned operations A TAC air cleaner is fundamentally made up of the following com ponents housing adjustable fan for air transport filter boxes for the integration of filter t...

Page 4: ...und Any unau thorised changes modifications or alterations of the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with ele...

Page 5: ...es must be connected as indicated in the figure below Fig 3 Connection diagram of pressure sensor hoses in the cleanroom arrangement Standard arrangement Here the motor is positioned as the last eleme...

Page 6: ...in the pre filter box Fig 6 b Bag filter arrangement wiring For proper monitoring of the filter technology the pressure sensor hoses must be connected as indicated in the figure below Fig 7 Connectio...

Page 7: ...led via a hose from the room into the air inlet of the device The purified air is fed through another hose from the air outlet and back into the room In ventilation mode the air to be cleaned is led v...

Page 8: ...nel Fig 12 Side view 2 of TAC 3000 without side panel Fig 13 Side view 2 of TAC 1500 without side panel Shutdown 1 Switch off the device 2 Remove the mains plug from the mains socket 3 Clean the devic...

Page 9: ...e mains plug with wet or damp hands Before any work detach the mains plug Maintenance tasks which require the housing to be opened must only be carried out by a specialist com pany or by TROTEC Filter...

Page 10: ...n the pre filter box and the fan housing 8 Mount the side panels Make sure that the side panels are grounded Fig 16 Removing the filter When the device warns of a spent pre filter and or HEPA filter s...

Page 11: ...horized changes of the facto ry supplied device version this declaration loses its legal validity Device version Air Cleaner Series TAC Year of manufacture as of April 2014 Applicable regulations Appl...

Page 12: ...200 250 Sound level distance 1 m 61 dBA 65 dBA Dimensions L x W x H 705 mm x 362 mm x 377 mm 833 mm x 460 mm x 519 mm Weight full 22 kg 36 kg Mobility portable wheeled stackable yes yes yes yes yes ye...

Page 13: ...und Abluftschlauch mit Filterkombination G4 H13 Zulassung f r Staubklasse H und Abluftschlauch empfohlene Luftmenge f r Staubklasse H 0 0 200 400 600 800 1 000 1 200 1 400 1 600 1 800 2 000 2 200 2 40...

Page 14: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 0 49 2452 962 200 info trotec com www trotec com...

Reviews: