SiBE01-503
Functions
Functions and Control
21
1.8
Other Functions
1.8.1
Hot Start Function
In order to prevent the cold draft that normally comes when heating operation starts, the
temperature of the indoor heat exchanger is detected, and either the air flow is stopped or is
made very weak thereby carrying out comfortable heating of the room.
*The cold draft is also prevented using a similar control when the thermostat turns OFF.
1.8.2
Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.8.3
ON/OFF Button on Indoor Unit
An ON/OFF button is provided on the front panel of the unit. Use this button when the remote
controller is missing or if its battery has run out.
Pressing the ON/OFF button cycles through the following operation modes: cooling
→
OFF
→
heating
→
OFF
→
cooling, etc. Since the operation mode is not displayed, you have to
judge what mode the unit is in by feeling whether the air coming out of the vent is cold or hot.
The operation mode refers to the following table.
1.8.4
Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter in a single highly effective unit. The filter traps microscopic particles, decompose odours
and even deactivates bacteria and viruses. It lasts for three years without replacement if
washed about once every six months.
1.8.5
Mold Proof Air Filter
The filter net is treated with mold resisting agent TBZ (harmless, colorless, and odorless). Due
to this treatment, the amount of mold growth is much smaller than that of normal filters.
1.8.6
Self-Diagnosis Digital Display
The microcomputer continuously monitors operating conditions of the indoor unit, the outdoor
unit, and the entire system. When an abnormality occurs, the remote controller displays error
code on the LCD. These indications allow prompt maintenance operations.
1.8.7
Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts in the condition before power failure automatically when power is restored.
(Note) It takes 3 minutes to restart the operation because the
3-minutes standby
function is
activated.
Mode
Temperature setting
Air flow rate
COOL
22°C
AUTO
HEAT
26°C
AUTO
Summary of Contents for ARY20DV2
Page 1: ...SiBE01 503 SPLIT Pair D Series Applied Models zNon Inverter Pair Heat Pump ...
Page 5: ...SiBE01 503 iv Table of Contents Index i Drawings Flow Charts iii ...
Page 10: ...SiBE01 503 List of Function 1 Part 1 List of Function 1 Functions 2 ...
Page 13: ...Functions SiBE01 503 4 List of Function ...
Page 14: ...SiBE01 503 Specifications 5 Part 2 Specifications 1 Specifications 6 ...
Page 35: ...Control Specification SiBE01 503 26 Functions and Control ...
Page 59: ...Instructions SiBE01 503 50 System Configuration ...
Page 79: ...Check SiBE01 503 70 Service Diagnosis ...
Page 117: ...Others SiBE01 503 108 Others ...