Removal Procedure
1.3
Removal of
Horizontal Blades /
Vertical Blades
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the horizontal
blades.
1
Lift horizontal blade to
open position.
Screw stoppers inside the
flap which were equipped in
the existing models are not
provided.
2
Disengage horizontal
blade from blade
retaining section.
3
Bend blade slightly and
remove it from the unit.