![background image](http://html.mh-extra.com/html/daikin/ary20dv2/ary20dv2_service-manual_501356104.webp)
SiBE01-503
Outdoor Unit
Removal Procedure
95
2
The
top plate
and the
front plate
are
constructed in a
monoblock. Remove
the three screws at the
right side and the two
screws at the front
plate.
3
Remove the three
screws at the left side.
4
Remove the one fixed
screw in the rear of the
top plate. Once lift the
top plate and then
remove it forward.
The
left side plate
and the
bellmouth can be removed
all at once.
When restoring the top plate,
move it horizontally and get
it down for the easy work.
5
The front plate and the
left side plate can be
removed when the one
fixed screw is removed.
Sectional view at the front.
Step
Procedure
Points
Top plate
Left side
plate
the top plate edge is
gotten into this groove.
(R1853)