Removal Procedure
99
2.5
Removal of
Sound Blanket
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. To remove the
right side
plate
.
1
Remove the three
screws for removing the
right side plate.
2
Lift the right side plate
to disengage the hooks.
Insert the three hooks for the
restoration.
2. To remove the sound
blanket
Since the sound blanket is
torn easily, remove it
carefully.
When restoring, the sound
blanket should pass the
internal side of the piping.
1
Untie the string of the
sound blanket.
(R4749)