![background image](http://html.mh-extra.com/html/daikin/altherma-ekhbh-series/altherma-ekhbh-series_service-manual_501281020.webp)
Specifications
ESIE06-03
1–20
3
11
4
5
2.4
EKSWW150~300V3/Z2
Technical
specifications
The table below contains the technical specifications.
Electrical
specifications
The table below contains the electrical specifications.
Specification
EKSWW150V3
EKSWW200V3
EKSWW300V3
EKSWW200Z2
EKSWW300Z2
Casing
Colour
Neutral white
Material
Epoxy-coated mild steel
Dimensions
Packing
Height
950 mm
1200 mm
1650 mm
1200 mm
1650 mm
Width
600 mm
Depth
600 mm
Unit
Height
900 mm
1150 mm
1600 mm
1150 mm
1600 mm
Width
580 mm
Depth
580 mm
Weight
Machine weigth
37 kg
45 kg
59 kg
45 kg
59 kg
Gross weight
40 kg
49 kg
64 kg
49 kg
64 kg
Packing
Material
EPS/Carton
Weight
3 kg
4 kg
5 kg
4 kg
5 kg
Main components
Tank
Water volume
150 l
200 l
300 l
200 l
300 l
Material
Stainless steel (DIN 1.4521)
Max. temperature
85°C
Max. water pressure
10 bar
Insulation Material
Polyurethane foam
Insulation Min. thickness
40 mm
Heat exchanger
Quantity
1
Material
Stainless steel (DIN 1.4401)
Booster heater
Quantity
1
Capacity
3 kW
Temperature sensor
Cable length
12 m
Piping connections
Water inlet H/E Diameter
3/4” FBSP (inch)
Water outlet H/E Diameter
3/4” FBSP (inch)
Cold water in Diameter
3/4” FBSP (inch)
Hot water out Diameter
3/4” FBSP (inch)
Specification
EKSWW150V3
EKSWW200V3
EKSWW300V3
EKSWW200Z2
EKSWW300Z2
Unit
Power supply
Phase
1~
2~
Frequency
50 Hz
Voltage
230 V
400 V
Nominal running current
13 A
7.5 A
Fuse Size
20 A
Phase
1~
2~
Summary of Contents for Altherma EKHBH Series
Page 2: ...ESIE06 03 1 2 Part 1 System Outline 3 1 1 5 ...
Page 26: ...Functional Diagrams ESIE06 03 1 26 Part 1 System Outline 3 1 1 4 5 ...
Page 32: ...Piping Diagrams ESIE06 03 1 32 Part 1 System Outline 3 1 1 4 5 ...
Page 38: ...Switch Box Layout ESIE06 03 1 38 Part 1 System Outline 3 1 1 4 5 ...
Page 58: ...PCB Layout ESIE06 03 1 58 Part 1 System Outline 3 1 1 4 5 ...
Page 60: ...ESIE06 03 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 68: ...Hydro box Functional Concept ESIE06 03 2 10 Part 2 Functional Description 3 1 2 4 5 ...
Page 88: ...ESIE06 03 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 134: ...Error Codes System Malfunctions ESIE06 03 3 48 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 152: ...Additional Checks for Troubleshooting ESIE06 03 3 66 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 154: ...ESIE06 03 5 2 Part 5 Disassembly and Maintenance 3 1 5 ...